All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Equalization of Medipix2 imaging detector energy thresholds using measurement of polychromatic X-ray beam attenuation

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F11%3A00191767" target="_blank" >RIV/68407700:21670/11:00191767 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1088/1748-0221/6/11/C11012" target="_blank" >http://dx.doi.org/10.1088/1748-0221/6/11/C11012</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/1748-0221/6/11/C11012" target="_blank" >10.1088/1748-0221/6/11/C11012</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Equalization of Medipix2 imaging detector energy thresholds using measurement of polychromatic X-ray beam attenuation

  • Original language description

    The single photon counting pixel detector Medipix2 is a powerful tool for energy resolved X-ray imaging. It allows the energies of incoming X-rays to be discriminated by setting an energy threshold common to all pixels. As the parameters of individual pixels vary, each pixel further contains a 3-bit digital-to-analogue converter (DAC) adjustment. Values of these DACs are traditionally determined by finding the noise floor in each pixel. Our approach is based on a polychromatic X-ray beam attenuation measurement. An attenuation curve is measured using varying thickness of aluminium foil. The attenuation curve is fitted in each pixel with a function calculating the detected signal. Free parameters of the fit are the beam intensity and the energy threshold. The measurement is done twice, with the threshold adjustment set to minimum resp. maximum value in all pixels. The result is a calibration of the adjustment DACs, allowing the value of the adjustment DAC in each pixel to be found such

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    BG - Nuclear, atomic and molecular physics, accelerators

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    Z - Vyzkumny zamer (s odkazem do CEZ)

Others

  • Publication year

    2011

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Instrumentation

  • ISSN

    1748-0221

  • e-ISSN

  • Volume of the periodical

    6

  • Issue of the periodical within the volume

  • Country of publishing house

    IT - ITALY

  • Number of pages

    8

  • Pages from-to

    1-8

  • UT code for WoS article

    000298320400012

  • EID of the result in the Scopus database