Dependence on temperature and pixel threshold of the calibration for the Timepix detector and its correction method

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F13%3A00217223" target="_blank" >RIV/68407700:21670/13:00217223 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1088/1748-0221/8/01/C01010" target="_blank" >http://dx.doi.org/10.1088/1748-0221/8/01/C01010</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/1748-0221/8/01/C01010" target="_blank" >10.1088/1748-0221/8/01/C01010</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Dependence on temperature and pixel threshold of the calibration for the Timepix detector and its correction method

  • Original language description

    The semiconductor pixel detector Timepix (matrix of 256 256 pixels with 55 mm pitch) can be used for measurements of energies of radiation quanta. For this purpose knowledge of the energy calibration of each pixel is required. Such a calibration is nonlinear. Two calibration methods already exist that use either monochromatic radiation sources or the internal test pulse capability. In the work we compare the calibrated response of the detector with the source method and for different temperatures and detector settings. Furthermore in this work we also explore the possibility of calibrating the detector under new conditions (temperature, detector settings) by adjusting an already existing calibration for different conditions. The new cross-temperature and cross-threshold calibration is calculated based on 3 original calibrations. This approach is advantageous, because it allows improving the detector response for different conditions without the need to make a whole new calibration. It

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    BG - Nuclear, atomic and molecular physics, accelerators

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/TA01010164" target="_blank" >TA01010164: Advanced Techniques for Detection of Ionizing Radiation</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Instrumentation

  • ISSN

    1748-0221

  • e-ISSN

  • Volume of the periodical

    8

  • Issue of the periodical within the volume

    8

  • Country of publishing house

    IT - ITALY

  • Number of pages

    7

  • Pages from-to

  • UT code for WoS article

    000320665400010

  • EID of the result in the Scopus database