The portable device for continual measurement of radon progenies on filter using the detector Timepix

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F15%3A00230405" target="_blank" >RIV/68407700:21670/15:00230405 - isvavai.cz</a>

  • Alternative codes found

    RIV/86652052:_____/15:#0000314

  • Result on the web

    <a href="http://dx.doi.org/10.1093/rpd/ncv343" target="_blank" >http://dx.doi.org/10.1093/rpd/ncv343</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1093/rpd/ncv343" target="_blank" >10.1093/rpd/ncv343</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    The portable device for continual measurement of radon progenies on filter using the detector Timepix

  • Original language description

    In this article, a portable device was presented for continual measuring of equilibrium equivalent concentration (EEC) of (222)Rn based on the Timepix detector with 300-m-thick active layer. In order to have a portable device, a filtration head was developed for collecting short-lived radon progenies attached on aerosols. The short-lived progenies are estimated from analysing alphas from decay of (218,214)Po from Millipore filter after termination of filtration. Comparison with beta measurement was done as well. The dependence of EEC on an air flow and filtration time was studied. The low-level detection limit for EEC was estimated from the last 10 min of 3-h decay measurement and was found in the range of 40-70 Bq m(-3). EEC was measured in National Radiation Protection Institute radon chamber, and results were compared with the commercial detector Fritra4.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    DL - Nuclear waste, radioactive pollution and control

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/TE01020445" target="_blank" >TE01020445: Radiation and nuclear safety technologies development center: RANUS - TD</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Radiation Protection Dosimetry

  • ISSN

    0144-8420

  • e-ISSN

  • Volume of the periodical

    164

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    4

  • Pages from-to

    493-496

  • UT code for WoS article

    000356726000008

  • EID of the result in the Scopus database