DANSS: Detector of the reactor AntiNeutrino based on Solid Scintillator
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F16%3A00309332" target="_blank" >RIV/68407700:21670/16:00309332 - isvavai.cz</a>
Alternative codes found
RIV/61389005:_____/16:00506282
Result on the web
<a href="http://dx.doi.org/10.1088/1748-0221/11/11/P11011" target="_blank" >http://dx.doi.org/10.1088/1748-0221/11/11/P11011</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/11/11/P11011" target="_blank" >10.1088/1748-0221/11/11/P11011</a>
Alternative languages
Result language
angličtina
Original language name
DANSS: Detector of the reactor AntiNeutrino based on Solid Scintillator
Original language description
The DANSS project is aimed at creating a relatively compact neutrino spectrometer which does not contain any flammable or other dangerous liquids and may therefore be located very close to the core of an industrial power reactor. As a result, it is expected that high neutrino flux would provide about 15,000 IBD interactions per day in the detector with a sensitive volume of 1 m<sup>3</sup>. High segmentation of the plastic scintillator will allow to suppress a background down to a ~1% level. Numerous tests performed with a simplified pilot prototype DANSSino under a 3 GW<inf>th</inf> reactor of the Kalinin NPP have demonstrated operability of the chosen design. The DANSS detector surrounded with a composite shield is movable by means of a special lifting gear, varying the distance to the reactor core in a range from 10 m to 12 m. Due to this feature, it could be used not only for the reactor monitoring, but also for fundamental research including short-range neutrino oscillations to the sterile state. Supposing one-year measurement, the sensitivity to the oscillation parameters is expected to reach a level of sin<sup>2</sup>(2θ<inf>new</inf>) ~ 5 x 10<sup>-3</sup> with Δ m<sup>2</sup> c (0.02-5.0) eV<sup>2</sup>.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
BG - Nuclear, atomic and molecular physics, accelerators
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/LG14004" target="_blank" >LG14004: Cooperation of Czech Republic with JINR Dubna in the theoretical and nuclear physics and application of nuclear methods in other fields</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Volume of the periodical
11
Issue of the periodical within the volume
11
Country of publishing house
IT - ITALY
Number of pages
26
Pages from-to
—
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-84999863236