APPARATUS FOR LOCALIZATION AND DOSIMETRY OF WOUNDS WITH RADIOACTIVE CONTAMINATION

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21670%2F22%3A00359258" target="_blank" >RIV/68407700:21670/22:00359258 - isvavai.cz</a>

  • Alternative codes found

    RIV/86652052:_____/22:N0000010

  • Result on the web

    <a href="https://doi.org/10.1093/rpd/ncac121" target="_blank" >https://doi.org/10.1093/rpd/ncac121</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1093/rpd/ncac121" target="_blank" >10.1093/rpd/ncac121</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    APPARATUS FOR LOCALIZATION AND DOSIMETRY OF WOUNDS WITH RADIOACTIVE CONTAMINATION

  • Original language description

    Disasters involving radioactive materials are one of the most dangerous accidents a living organism can be exposed to. Individuals and first responders are in risk during accidents or interventions, due to radioactive debris impact, due to the use of depleted uranium ammunition or a malevolent act against individuals. Moreover, radioactive contamination of wounds causes internal exposure in the body and standard decontamination procedures cannot be applied. In order to deal with such situations, we are developing a measurement system consisting of a robotic arm, an array of various detectors and a corresponding methodology, which allows quantifying timely the spatial distribution of contamination and the radiation dose for the adequate medical response. The aim of this publication is to the present current status of the development of the described apparatus.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20305 - Nuclear related engineering; (nuclear physics to be 1.3);

Result continuities

  • Project

    <a href="/en/project/VI20192022136" target="_blank" >VI20192022136: Detector of the radioactive contamination in wounds</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Radiation Protection Dosimetry

  • ISSN

    0144-8420

  • e-ISSN

    1742-3406

  • Volume of the periodical

    198

  • Issue of the periodical within the volume

    198

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    5

  • Pages from-to

    693-697

  • UT code for WoS article

    000844405700035

  • EID of the result in the Scopus database