Moisture problems in a narrow gap under the suspended floor: A case study

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21720%2F14%3A00224447" target="_blank" >RIV/68407700:21720/14:00224447 - isvavai.cz</a>

  • Result on the web

    <a href="http://www.nsb2014.se/" target="_blank" >http://www.nsb2014.se/</a>

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Moisture problems in a narrow gap under the suspended floor: A case study

  • Original language description

    This paper presents and explains moisture problems observed in the sub-floor space of a timber-framed kindergarten in the Central European climate. The floor structure (36 by 52 m) is suspended 0.27 m above the uncovered ground surface. The sub-floor ismechanically ventilated in one direction. Here, relative humidity constantly exceeds 95 % irrespective of the season. Furthermore, visual inspections revealed condensation and mould growth in the inlet area. A two-dimensional dynamic HAM model was written in Matlab in order to describe the sub-floor?s behaviour and evaluate possible actions. The model was validated using measured data. The results show two principal moisture sources: (1) evaporation from the ground and (2) ventilation by the outdoor air. The ground source is active throughout the year and causes gradual increase in relative humidity in the direction of the flow. The outdoor air brings in excessive moisture from spring to autumn and causes condensation on the floor struc

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JN - Civil engineering

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/ED2.1.00%2F03.0091" target="_blank" >ED2.1.00/03.0091: University center for energy Efficient buildings (UCEEB)</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    10th Nordic Symposium on Building Physics

  • ISBN

    978-91-88722-53-9

  • ISSN

  • e-ISSN

  • Number of pages

    8

  • Pages from-to

    1006-1013

  • Publisher name

    Lund University

  • Place of publication

    Lund

  • Event location

    Lund

  • Event date

    Jun 15, 2014

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article