All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Visually validated semi-automatic high-frequency oscillation detection aides the delineation of epileptogenic regions during intra-operative electrocorticography

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21730%2F18%3A00327734" target="_blank" >RIV/68407700:21730/18:00327734 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.sciencedirect.com/science/article/pii/S1388245718311568" target="_blank" >https://www.sciencedirect.com/science/article/pii/S1388245718311568</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.clinph.2018.06.030" target="_blank" >10.1016/j.clinph.2018.06.030</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Visually validated semi-automatic high-frequency oscillation detection aides the delineation of epileptogenic regions during intra-operative electrocorticography

  • Original language description

    Objective To test the utility of a novel semi-automated method for detecting, validating, and quantifying high-frequency oscillations (HFOs): ripples (80–200 Hz) and fast ripples (200–600 Hz) in intra-operative electrocorticography (ECoG) recordings. Methods Sixteen adult patients with temporal lobe epilepsy (TLE) had intra-operative ECoG recordings at the time of resection. The computer-annotated ECoG recordings were visually inspected and false positive detections were removed. We retrospectively determined the sensitivity, specificity, positive and negative predictive value (PPV/NPV) of HFO detections in unresected regions for determining post-operative seizure outcome. Results Visual validation revealed that 2.81% of ripple and 43.68% of fast ripple detections were false positive. Inter-reader agreement for false positive fast ripple on spike classification was good (ICC = 0.713, 95% CI: 0.632–0.779). After removing false positive detections, the PPV of a single fast ripple on spike in an unresected electrode site for post-operative non-seizure free outcome was 85.7 [50–100%]. Including false positive detections reduced the PPV to 64.2 [57.8–69.83%]. Conclusions Applying automated HFO methods to intraoperative electrocorticography recordings results in false positive fast ripple detections. True fast ripples on spikes are rare, but predict non-seizure free post-operative outcome if found in an unresected site. Significance Semi-automated HFO detection methods are required to accurately identify fast ripple events in intra-operative ECoG recordings.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>ost</sub> - Miscellaneous article in a specialist periodical

  • CEP classification

  • OECD FORD branch

    10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Clinical Neurophysiology

  • ISSN

    1388-2457

  • e-ISSN

    1872-8952

  • Volume of the periodical

    129

  • Issue of the periodical within the volume

    10

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    10

  • Pages from-to

    2089-2098

  • UT code for WoS article

  • EID of the result in the Scopus database