Neutron Energy Reconstruction and Fluence Determination at 27 keV With the LNE-IRSN-MIMAC MicroTPC Recoil Detector

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A90072%2F16%3A00344296" target="_blank" >RIV/68407700:90072/16:00344296 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1109/TNS.2016.2527819" target="_blank" >https://doi.org/10.1109/TNS.2016.2527819</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/TNS.2016.2527819" target="_blank" >10.1109/TNS.2016.2527819</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Neutron Energy Reconstruction and Fluence Determination at 27 keV With the LNE-IRSN-MIMAC MicroTPC Recoil Detector

  • Original language description

    The aim is to characterize the energy distribution of neutron fluence in the energy range 8 keV-5 MeV based on a primary standard: the LNE-IRSN/MIMAC microTPC. The microTPC is a time projection chamber. Time projection chambers are gaseous detectors able to measure charged particles energy and to reconstruct their track. The gas is used as a (n, p) converter in order to detect neutrons down to few keV. The neutron energy is reconstructed event by event thanks to proton scattering angle and proton ionization energy measurements. The scattering angle is deduced from the 3-D track. The proton energy is obtained by charge collection measurements, knowing the ionization quenching factor. The fluence is reconstructed thanks to the detected events number and the simulation of the detector response. The microTPC is a new reliable detector able to measure energy distribution of the neutron fluence without unfolding procedure or prior neutron calibration contrary to usual gaseous counters. The microTPC is characterized at the AMANDE facility, with neutron energies going from 8 keV to 565 keV. This work shows the first direct reconstruction of neutron energy and fluence, simultaneously, at 27.2 keV in a continuous irradiation mode.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10304 - Nuclear physics

Result continuities

  • Project

  • Continuities

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    IEEE Transactions on Nuclear Science

  • ISSN

    0018-9499

  • e-ISSN

    1558-1578

  • Volume of the periodical

    63

  • Issue of the periodical within the volume

    3

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    8

  • Pages from-to

    1934-1941

  • UT code for WoS article

    000382463600028