All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Performance of the EDELWEISS-III experiment for direct dark matter searches

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A90072%2F17%3A00344156" target="_blank" >RIV/68407700:90072/17:00344156 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1088/1748-0221/12/08/P08010" target="_blank" >https://doi.org/10.1088/1748-0221/12/08/P08010</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/1748-0221/12/08/P08010" target="_blank" >10.1088/1748-0221/12/08/P08010</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Performance of the EDELWEISS-III experiment for direct dark matter searches

  • Original language description

    We present the results of measurements demonstrating the efficiency of the EDELWEISS-III array of cryogenic germanium detectors for direct dark matter searches. The experimental setup and the FID (Fully Inter-Digitized) detector array is described, as well as the efficiency of the double measurement of heat and ionization signals in background rejection. For the whole set of 24 FID detectors used for coincidence studies, the baseline resolutions for the fiducial ionization energy are mainly below 0.7 keV(ee) (FHWM) whereas the baseline resolutions for heat energies are mainly below 1.5 keV(ee) (FWHM). The response to nuclear recoils as well as the very good discrimination capability of the FID design has been measured with an AmBe source. The surface beta- and alpha-decay rejection power of R-surf < 4 x 10(-5) per alpha at 90% C. L. has been determined with a 210Pb source, the rejection of bulk gamma-ray events has been demonstrated using gamma-calibrations with (133B)a sources leading to a value of R gamma(-mis-fid) < 2 : 5 x 10(-6) at 90% C. L.. The current levels of natural radioactivity measured in the detector array are shown as the rate of single gamma background. The fiducial volume fraction of the FID detectors has been measured to a weighted average value of (74.6 +/- 0.4)% using the cosmogenic activation of the Zn-65 and Ge-68,Ge-71 isotopes. The stability and uniformity of the detector response is also discussed. The achieved resolutions, thresholds and background levels of the upgraded EDELWEISS-III detectors in their setup are thus well suited to the direct search of WIMP dark matter over a large mass range.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10304 - Nuclear physics

Result continuities

  • Project

  • Continuities

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Instrumentation

  • ISSN

    1748-0221

  • e-ISSN

    1748-0221

  • Volume of the periodical

    12

  • Issue of the periodical within the volume

    P08010

  • Country of publishing house

    IT - ITALY

  • Number of pages

    46

  • Pages from-to

    1-46

  • UT code for WoS article

    000414159500010

  • EID of the result in the Scopus database