All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Mo-100-enriched Li2MoO4 scintillating bolometers for 0 nu 2 beta decay search: from LUMINEU to CUPID-0/Mo projects

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A90072%2F17%3A00344191" target="_blank" >RIV/68407700:90072/17:00344191 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1063/1.5007642" target="_blank" >https://doi.org/10.1063/1.5007642</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1063/1.5007642" target="_blank" >10.1063/1.5007642</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Mo-100-enriched Li2MoO4 scintillating bolometers for 0 nu 2 beta decay search: from LUMINEU to CUPID-0/Mo projects

  • Original language description

    A scintillating bolometer technology based on Mo-100-enriched lithium molybdate (Li-2 (MoO4)-Mo-100) crystals has been developed by LUMINEU to search for neutrinoless double-beta (0 nu 2 beta) decay of Mo-100. The results of several low temperature tests at underground environments have proved the reproducibility of high detector performance and crystal radiopurity: in particular similar to 5-6 keV FWHM energy resolution and at least 9 sigma rejection of alpha's in the vicinity of the 0.2 beta decay of Mo-100 (3034 keV) and below 10 mu Bq/kg bulk activity of Th-228 and Ra-226. A modest acquired exposure (0.1 kgxyr) is a limiting factor of the LUMINEU experiment sensitivity to the 0 nu 2 beta decay half-life of Mo-100 (T-1/2 >= 0.7x10(23) yr at 90% C.L.), however the two-neutrino 2 beta decay has been measured with the best up to-date accuracy, T-1/2 = [6.92 +/- 0.06(stat.) +/- 0.36(syst.)] x 10(18) yr. The applicability of the LUMINEU technology for a tonne-scale 0.2 beta decay bolometric project CUPID is going to be demonstrated by the CUPID-0/Mo experiment with similar to 5 kg of Mo-100 embedded in forty 0.2 kg Li-2 (MoO4)-Mo-100 scintillating bolometers. A first phase of the experiment with twenty Li-2 (MoO4)-Mo-100 detectors is in preparation at the Modane underground laboratory (France) to start by the end of 2017.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    10304 - Nuclear physics

Result continuities

  • Project

  • Continuities

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Workshop on Calculation of Double-Beta-Decay Matrix Elements (MEDEX´17)

  • ISBN

    978-0-7354-1577-5

  • ISSN

    0094-243X

  • e-ISSN

  • Number of pages

    4

  • Pages from-to

    1-4

  • Publisher name

    AIP Conference Proceedings

  • Place of publication

    New York

  • Event location

    Praha

  • Event date

    May 29, 2017

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000417388100017