All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Search for sub-GeV dark matter via the Migdal effect with an EDELWEISS germanium detector with NbSi transition-edge sensors

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A90107%2F22%3A00363782" target="_blank" >RIV/68407700:90107/22:00363782 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1103/PhysRevD.106.062004" target="_blank" >https://doi.org/10.1103/PhysRevD.106.062004</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1103/PhysRevD.106.062004" target="_blank" >10.1103/PhysRevD.106.062004</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Search for sub-GeV dark matter via the Migdal effect with an EDELWEISS germanium detector with NbSi transition-edge sensors

  • Original language description

    The EDELWEISS collaboration reports on the search for dark matter particle interactions via Migdal effect with masses between 32 MeV . c-2 to 2 GeV . c-2 using a 200 g cryogenic Ge detector sensitive to simultaneously heat and ionization signals and operated underground at the Laboratoire Souterrain de Modane in France. The phonon signal was read out using a transition edge sensor made of a NbSi thin film. The detector was biased at 66 V in order to benefit from the Neganov-Trofimov-Luke amplification and resulting in a resolution on the energy of electron recoils of 4.46 eVee (102.58 eV at 66 V) and an analysis threshold of 30 eVee. The sensitivity is limited by a dominant background not associated to charge creation in the detector. The search constrains a new region of parameter space for cross sections down to 10-29 cm2 and masses between 32 and 100 MeV . c-2. The achieved low threshold with the NbSi sensor shows the relevance of its use for out-of-equilibrium phonon sensitive devices for low-mass dark matter searches.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10304 - Nuclear physics

Result continuities

  • Project

  • Continuities

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Physical Review D

  • ISSN

    2470-0010

  • e-ISSN

    2470-0029

  • Volume of the periodical

    106

  • Issue of the periodical within the volume

    6

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    10

  • Pages from-to

    "062004-1"-"062004-10"

  • UT code for WoS article

    000916404500009

  • EID of the result in the Scopus database

    2-s2.0-85139627301