Simultaneous Measurements of Nanoaerosols and Radioactive Aerosols Containing the Short-lived Radon Isotopes
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70565813%3A_____%2F17%3AN0000003" target="_blank" >RIV/70565813:_____/17:N0000003 - isvavai.cz</a>
Alternative codes found
RIV/67985858:_____/17:00478191
Result on the web
<a href="https://academic.oup.com/rpd/article-abstract/177/1-2/53/4161658?redirectedFrom=fulltext" target="_blank" >https://academic.oup.com/rpd/article-abstract/177/1-2/53/4161658?redirectedFrom=fulltext</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncx157" target="_blank" >10.1093/rpd/ncx157</a>
Alternative languages
Result language
angličtina
Original language name
Simultaneous Measurements of Nanoaerosols and Radioactive Aerosols Containing the Short-lived Radon Isotopes
Original language description
The activity size distribution of the Equilibrium-Equivalent Concentration (EER) of 222Rn is one of the most important parameters for the estimation of radiation dose by inhalation of radon decay products. A series of measurements of the EER activity size distribution were performed by the screen diffusion battery in Radon-Aerosol chamber (10m3) at the National Institute for Nuclear, Chemical, and Biological Protection (SUJCHBO). These measurements were performed at different levels of radon concentration. For this study, the Graded Screen Array Diffusion Battery (GSA DB), developed by the SUJCHBO (based on Earl Knutson and Robert F Holub design), consists of 10 screens and backup filter used to collect all particles that penetrated the screens. The measuring range of this GSA DB allows measuring the radioactive nanoaerosols in the size range from 0.5 to 100 nm. The Earl Knutson algorithm was used for EER activity size distribution evaluation. The results of EER activity size distribution were subsequently compared with the aerosol particle size distribution measured by Scanning Mobility Particle Sizer Spectrometer (SMPS 3936 N, TSI Inc., MN, USA).
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10304 - Nuclear physics
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
1742-3406
Volume of the periodical
177
Issue of the periodical within the volume
1-2
Country of publishing house
GB - UNITED KINGDOM
Number of pages
4
Pages from-to
53-56
UT code for WoS article
000417604700013
EID of the result in the Scopus database
—