Influence of temperature and transmitted power on losses in particular transmission system
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F22%3A63556239" target="_blank" >RIV/70883521:28140/22:63556239 - isvavai.cz</a>
Alternative codes found
RIV/61988987:17450/22:A2302FHW
Result on the web
<a href="https://wseas.com/journals/ps/2022/a125116-005(2022).pdf" target="_blank" >https://wseas.com/journals/ps/2022/a125116-005(2022).pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.37394/232016.2022.17.6" target="_blank" >10.37394/232016.2022.17.6</a>
Alternative languages
Result language
angličtina
Original language name
Influence of temperature and transmitted power on losses in particular transmission system
Original language description
Innovations and trends has been significantly increased during modern theory and practical realizations in the field of energetic. In the Czech Republic, the research of predictions of technical losses on the transmission system can be considered as novel and important topic. Using software possibilities can be appropriately utilized in the frame of estimations of the technical losses. While they cannot be eliminated, they may be minimized. Losses can be measured or calculated using transmission-line parameters. This causality is considered in the form of the presented and proposed mathematical equations including real measured data of the atmospheric temperatures achieved on the substations selected in the Moravian-Silesian region. In this contribution, results of proposed calculations of technical losses based only on line parameters considering the ambient temperature are being compared in relation to a particular transmission system using prediction software. Particularly, technical losses caused by a configuration change of a selected part of a transmission system are considered related to the operation of Dlouhe Strane pumped storage hydro power plant. As can be conclude, after the resulted comparisons using by the proposed mathematical models in software and the obtained real measured data, general minimization of the losses is necessary to create the most accurate models of the states that might occur in the future and to propose required modifications of the given part of the transmission system. Future bounded research can be focused on the sensors situated on the transmission lines instead of the substations.
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
20205 - Automation and control systems
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
WSEAS Transactions on Power Systems
ISSN
1790-5060
e-ISSN
—
Volume of the periodical
17
Issue of the periodical within the volume
Neuveden
Country of publishing house
GR - GREECE
Number of pages
9
Pages from-to
53-61
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-85129793213