Computational analysis of indoor thermal comfort in a terraced family house with thermal insulation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28140%2F23%3A63569178" target="_blank" >RIV/70883521:28140/23:63569178 - isvavai.cz</a>
Alternative codes found
RIV/68407700:21730/23:00371382 RIV/60461373:22340/23:43928187
Result on the web
<a href="https://ieeexplore.ieee.org/document/10164094" target="_blank" >https://ieeexplore.ieee.org/document/10164094</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ACCESS.2023.3290097" target="_blank" >10.1109/ACCESS.2023.3290097</a>
Alternative languages
Result language
angličtina
Original language name
Computational analysis of indoor thermal comfort in a terraced family house with thermal insulation
Original language description
Computer simulations are used to assess the impact of thermal insulation on the transfer of heat and moisture in the exterior walls of residential buildings. The effects of internal and external thermal insulation on a room in a terraced family house are compared using the COMSOL Multiphysics software package, evaluating the influence of the placement of expanded polystyrene thermal insulation on the distribution of heat and moisture in the external wall while monitoring the indoor air temperature during the heating and cooling regimes. The internal thermal insulation is more efficient in terms of room heating, while the external insulation is preferable in reducing the risk of the condensation water vapor within the wall. The efficiency of heating the room to 20°C increased by 12% when internal thermal insulation was added to the walls, compared to heating without insulation. The maximum value of relative humidity in the critical wall section decreased by 10% when external thermal insulation was added. Implementing internal thermal insulation needs the right choice of insulation material and its installation to prevent air leakage. The results suggest that the proper selection of the placement of the thermal insulation is critical for optimizing the thermal performance and reducing moisture-related problems in residential buildings. Author
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
IEEE Access
ISSN
2169-3536
e-ISSN
2169-3536
Volume of the periodical
11
Issue of the periodical within the volume
Neuveden
Country of publishing house
US - UNITED STATES
Number of pages
1
Pages from-to
80822-80834
UT code for WoS article
001045243200001
EID of the result in the Scopus database
2-s2.0-85163516868