Retinal oxygen saturation is associated with HbA1c but not with short-term diabetes control, internal environment, smoking and mild retinopathy - ROXINEGLYD study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70883521%3A28150%2F21%3A63527578" target="_blank" >RIV/70883521:28150/21:63527578 - isvavai.cz</a>
Alternative codes found
RIV/00098892:_____/22:10157565 RIV/61989592:15110/22:73615780
Result on the web
<a href="https://onlinelibrary.wiley.com/doi/10.1111/aos.14853" target="_blank" >https://onlinelibrary.wiley.com/doi/10.1111/aos.14853</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/aos.14853" target="_blank" >10.1111/aos.14853</a>
Alternative languages
Result language
angličtina
Original language name
Retinal oxygen saturation is associated with HbA1c but not with short-term diabetes control, internal environment, smoking and mild retinopathy - ROXINEGLYD study
Original language description
Purpose: Purpose of this prospective uncontrolled single-centre pilot study was to find an association of retinal oxygen saturation (SatO2) with acid–base balance (ABB), carboxyhaemoglobin concentration, current plasma glucose concentration (PG), mean PG and PG variability over the last 72 hr, haemoglobin A1c (HbA1c), and other conditions. Methods: Forty-one adults (17 men) with type 1 (N = 14) or type 2 (N = 27) diabetes mellitus, age 48.6 ± 13.5 years, diabetes duration 9 (0.1–36) years, BMI 29.4 ± 6.3 kg/m2, and HbA1c 52 ± 12.7 mmol/mol completed the study. The 4-day study comprised two visits (Day l, Day 4) including 72 hr of continuous glucose monitoring (CGM) by iPro®2 Professional CGM (Medtronic, MiniMed, Inc., Northridge, CA, USA). Retinal oximeter Oxymap T1 (Oxymap ehf., Reykjavik, Iceland) was used to assess SatO2. Results: Wilcoxon signed-rank test showed no SatO2 difference between eyes and visits. Spearman's correlation analysis revealed a significant correlation between arterial SatO2 and PG variability in type 2 diabetes mellitus, a positive correlation of venous SatO2 with HbA1c and with finger pulse oximetry. However, no correlation of SatO2 with ABB, carboxyhaemoglobin, current PG, mean PG over the 72 hr, age, diabetes duration, BMI, lipoproteinaemia, body temperature, systolic and diastolic blood pressure, heart rate, central retinal thickness and retinal nerve fibre layer thickness was found. Conclusion: This study confirmed the association of venous SatO2 with long-term but not with short-term diabetes control, ABB and other conditions. The increased SatO2 and questionable impact of PG variability on retinal SatO2 is a research challenge.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30307 - Nursing
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Acta Ophthalmologica
ISSN
1755-375X
e-ISSN
—
Volume of the periodical
100
Issue of the periodical within the volume
1
Country of publishing house
US - UNITED STATES
Number of pages
8
Pages from-to
"E142"-"E149"
UT code for WoS article
000630653400001
EID of the result in the Scopus database
2-s2.0-85102779045