Sensitivity of zebrafish (Danio rerio) embryos to hospital effluent compared to Daphnia magna and Aliivibrio fischeri
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F75010330%3A_____%2F20%3A00013463" target="_blank" >RIV/75010330:_____/20:00013463 - isvavai.cz</a>
Alternative codes found
RIV/60460709:41330/20:88239
Result on the web
<a href="http://www.biomed.cas.cz/physiolres/2020/S4_20.htm" target="_blank" >http://www.biomed.cas.cz/physiolres/2020/S4_20.htm</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.33549/physiolres.934616" target="_blank" >10.33549/physiolres.934616</a>
Alternative languages
Result language
angličtina
Original language name
Sensitivity of zebrafish (Danio rerio) embryos to hospital effluent compared to Daphnia magna and Aliivibrio fischeri
Original language description
The Fish Embryo Acute Toxicity (FET) Test was adopted by the Organisation for Economic Co-operation and Development as OECD TG 236 in 2013. The test has been designed to determine acute toxicity of chemicals on embryonic stages of fish and proposed as an alternative method to the Fish Acute Toxicity Test performed according to OECD TG 203. In recent years fish embryos were used not only in the assessment of toxicity of chemicals but also for environmental and wastewater samples. In our study we investigated the acute toxicity of treated wastewater from seven hospitals in the Czech Republic. Our main purpose was to compare the suitability and sensitivity of zebrafish embryos with the sensitivity of two other aquatic organisms commonly used for wastewater testing - Daphnia magna and Aliivibrio fischeri. For the aim of this study, in addition to the lethal endpoints of the FET test, sublethal effects such as delayed heartbeat, lack of blood circulation, pericardial and yolk sac edema, spinal curvature and pigmentation failures were evaluated. The comparison of three species demonstrated that the sensitivity of zebrafish embryos is comparable or in some cases higher than the sensitivity of D. magna and A. fischeri. The inclusion of sublethal endpoints caused statistically significant increase of the FET test efficiency in the range of 1-12 %. Based on our results, the FET test, especially with the addition of sublethal effects evaluation, can be considered as a sufficiently sensitive and useful additional tool for ecotoxicity testing of the acute toxicity potential of hospital effluents.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30108 - Toxicology
Result continuities
Project
<a href="/en/project/EF16_019%2F000860" target="_blank" >EF16_019/000860: International competitiveness of NIPH in research, development and education in alternative toxicological methods.</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Physiological Research
ISSN
0862-8408
e-ISSN
1802-9973
Volume of the periodical
69
Issue of the periodical within the volume
Suppl. 4
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
11
Pages from-to
„S681“-„S691“
UT code for WoS article
000621838200013
EID of the result in the Scopus database
2-s2.0-85102482246