Indoor Environment in Residential Prefabricated Buildings
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F75081431%3A_____%2F17%3A00001181" target="_blank" >RIV/75081431:_____/17:00001181 - isvavai.cz</a>
Result on the web
<a href="http://iopscience.iop.org/article/10.1088/1757-899X/245/4/042072/pdf" target="_blank" >http://iopscience.iop.org/article/10.1088/1757-899X/245/4/042072/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/245/4/042072" target="_blank" >10.1088/1757-899X/245/4/042072</a>
Alternative languages
Result language
angličtina
Original language name
Indoor Environment in Residential Prefabricated Buildings
Original language description
The contribution presents results of the experimental measurement of indoor air quality in residential prefabricated buildings. People spend about 90% of their life in the indoor environment of buildings. Hygrothermal parameters and indoor air quality are the essential component that define the quality of the indoor environment. The results of case study characterize the quality of the indoor environment of the ordinary occupants in housing unit of residential prefabricated building. A current problem of revitalized prefabricated buildings is inadequate air exchange and related thereto to poor indoor air quality. The experimental measurements were carried out just before and at the beginning of the heating season (from 1st October to 30th November 2016). Heating season was launched in the middle of experimental measurement. The wireless indoor sensor Elgato Eve Room was used for measurements. The obtained values of indoor air temperature [C], relative humidity [%] and indoor air quality [ppm] are describe and analysis in this study. The results of the study indicate that the values of temperature and indoor air quality meet optimal levels during the experiment with nuances. The mean air temperature in the indoor environment is 22.43 C. The temperature of the indoor environment is held at the optimum level (18-24 C) for 94.50% time of the experimental measurements. In addition, the indoor air quality in the context of the content of harmful volatile organic compounds (VOCs) has been excellent for almost 91% time of the total experiment. However, the values of relative humidity were less than the optimum value nearly 40% of the total observed time. The mean 10-minutes values of relative humidity during the heating season is about 10% lower than the mean 10-minutes relative humidity before the heating season.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
20101 - Civil engineering
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
IOP Conference Series: Materials Science and Engineering, Volume 245, Issue 4 (World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium 2017)
ISBN
—
ISSN
1757-8981
e-ISSN
—
Number of pages
7
Pages from-to
—
Publisher name
Institute of Physics Publishing
Place of publication
Spojené království
Event location
Praha (Česká republika)
Event date
Jun 12, 2017
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—