Defects of roofing and roof structure-Apartment house Kaplice

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F75081431%3A_____%2F19%3A00001603" target="_blank" >RIV/75081431:_____/19:00001603 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1088/1757-899X/603/5/052088" target="_blank" >http://dx.doi.org/10.1088/1757-899X/603/5/052088</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/1757-899X/603/5/052088" target="_blank" >10.1088/1757-899X/603/5/052088</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Defects of roofing and roof structure-Apartment house Kaplice

  • Original language description

    The aim of paper is to provide information on the defects of roofing and roof structure on Apartment house Kaplice. Roof cover is Beronit fiber-cement template cover. The roof template is 400 x 400 mm (square with corrugated corners). The roof was laid according to design documentation and documented invoices 10 years ago. The roof as a whole, as a result of very serious defects, does not fulfill its function (protection of the object from weathering). The rainwater penetrates into the attic and affects the wooden elements of the roof structure. Wooden elements of truss construction, in particular formwork and rafters in the ridge area, are infested with mold. The Czech Mycological Society confirmed the attack of wood mold elements, testing the samples taken. One sample from the inside face of the roof formwork has higher mold values, and the other sample has even high mold values. The attic space can only be ventilated through the opening windows and the roofing is designed as unpaved. During the ten-year lifetime of the roofing, one repair was carried out, which further aggravated the condition. The detected state of the roof is emergency and the implemented measure in the form of capturing penetrated water into plastic containers is not enough to stop the deepening of destructive roof processes. Temporary repairs to roof roofing did not benefit, and on the contrary, it is one of the main factors causing cracking and shading of roofing patterns and thus the penetration of rainwater into the soil.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20101 - Civil engineering

Result continuities

  • Project

  • Continuities

    V - Vyzkumna aktivita podporovana z jinych verejnych zdroju

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    IOP Conference Series: Materials Science and Engineering

  • ISBN

  • ISSN

    1757-8981

  • e-ISSN

  • Number of pages

    6

  • Pages from-to

    1-6

  • Publisher name

    Institute of Physics Publishing

  • Place of publication

    Spojené království

  • Event location

    Praha, Česká republika

  • Event date

    Jun 17, 2019

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article