All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Monte Carlo simulation of the BEGe detector response function for in vivo measurements of 241Am in the skull

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F14%3A%230000254" target="_blank" >RIV/86652052:_____/14:#0000254 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.radphyschem.2014.01.005" target="_blank" >http://dx.doi.org/10.1016/j.radphyschem.2014.01.005</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.radphyschem.2014.01.005" target="_blank" >10.1016/j.radphyschem.2014.01.005</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Monte Carlo simulation of the BEGe detector response function for in vivo measurements of 241Am in the skull

  • Original language description

    This paper reports on the procedure of the BEGe detector characterization for the Monte Carlo calibrations. A project is under way to improve the counting and operating capabilities of the Whole Body Counter (WBC) installed in SURO, v.v.i. (NRPI) Prague,Czech Republic. Possible emergency monitoring should mainly benefit from the rapid, safe and flexible operation of the WBC. The system of the WBC for the detection of low energy X and gamma radiation comprises four HPGe detectors intended for the routine, emergency, and research measurements of persons internally contaminated with low-energy photon emitters, mainly actinides. Among them, Am-241 is the main subject of interest. A precise detection efficiency calibration of the detector is required for the measurement of activity in individual organs and tissues. The use of physical phantoms in the calibrations is often supplemented with the application of voxel phantoms and a Monte Carlo technique that are used for the calculation of th

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    DL - Nuclear waste, radioactive pollution and control

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/VG20122014093" target="_blank" >VG20122014093: Instruments for monitoring of internal contamination in thyroide, especially of children, and transuranium radionuclide following nuclear plant accident</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Radiation Physics and Chemistry

  • ISSN

    0969-806X

  • e-ISSN

  • Volume of the periodical

    104

  • Issue of the periodical within the volume

    November

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    6

  • Pages from-to

    345-350

  • UT code for WoS article

    000341463600072

  • EID of the result in the Scopus database