Monte Carlo simulation of the Bremsstrahlung radiation for the measurement ofan internal contamination with pure-beta emitters in vivo
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F16%3AN0000022" target="_blank" >RIV/86652052:_____/16:N0000022 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1093/rpd/ncv427" target="_blank" >http://dx.doi.org/10.1093/rpd/ncv427</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncv427" target="_blank" >10.1093/rpd/ncv427</a>
Alternative languages
Result language
angličtina
Original language name
Monte Carlo simulation of the Bremsstrahlung radiation for the measurement ofan internal contamination with pure-beta emitters in vivo
Original language description
Rapid measurement techniques are required for a large-scale emergency monitoring of people. In vivo measurement of the bremsstrahlung radiation produced by incorporated pure-beta emitters can offer a rapid technique for the determination of such radionuclides in the human body. This work presents a method for the calibration of spectrometers, based on the use of UPh-02T (so-called IGOR) phantom and specific 90Sr/90Y sources, which can account for recent as well as previous contaminations. The process of the whole- and partial-body counter calibration in combination with application of a Monte Carlo code offers readily extension also to other pure-beta emitters and various exposure scenarios.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
DL - Nuclear waste, radioactive pollution and control
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/VF20102015014" target="_blank" >VF20102015014: Research of advanced methods of detection, estimation and management of resulting radioactive contamination</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
—
Volume of the periodical
170
Issue of the periodical within the volume
1-4
Country of publishing house
GB - UNITED KINGDOM
Number of pages
5
Pages from-to
354-358