X-ray tube spectra measurement and correction using a CdTe detector and an analytic response matrix for photon energies up to 160 keV

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F16%3AN0000031" target="_blank" >RIV/86652052:_____/16:N0000031 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.radmeas.2015.12.008" target="_blank" >http://dx.doi.org/10.1016/j.radmeas.2015.12.008</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.radmeas.2015.12.008" target="_blank" >10.1016/j.radmeas.2015.12.008</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    X-ray tube spectra measurement and correction using a CdTe detector and an analytic response matrix for photon energies up to 160 keV

  • Original language description

    The spectra of five “narrow-spectrum series” beams, namely N60 to N150, were measured with a spectrometry system consisting of the Amptek XR-100T X-ray semiconductor detector and the PX5 multichannel analyser. The response matrix R(E, E') of the detector was constructed which quantifies the energy dependence of the relative detection efficiency of the detector, the probabilities of the escape effects, and the probability of the Compton effect. A single matrix operation was applied to recover the physical energy spectra from the measured instrumental ones. The parameters of the corrected spectra were compared with the published and reference data. A fully satisfying quantitative correspondence was observed between the measured corrected spectra and the available reference data.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FS - Medical facilities, apparatus and equipment

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Radiation Measurements

  • ISSN

    1350-4487

  • e-ISSN

  • Volume of the periodical

    85

  • Issue of the periodical within the volume

    February

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    7

  • Pages from-to

    64-72

  • UT code for WoS article

    000370089600008