The use of the Exradin W1 plastic scintillator for measurements in external radiotherapy
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F19%3AN0000002" target="_blank" >RIV/86652052:_____/19:N0000002 - isvavai.cz</a>
Alternative codes found
RIV/00064203:_____/19:10410588
Result on the web
<a href="https://academic.oup.com/rpd/advance-article/doi/10.1093/rpd/ncz230/5643637" target="_blank" >https://academic.oup.com/rpd/advance-article/doi/10.1093/rpd/ncz230/5643637</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncz230" target="_blank" >10.1093/rpd/ncz230</a>
Alternative languages
Result language
angličtina
Original language name
The use of the Exradin W1 plastic scintillator for measurements in external radiotherapy
Original language description
The Exradin W1 plastic scintillator (Standard Imaging) was examined for measurement suitability in high-energy photon beams, high-energy electron beams and tomotherapy in terms of dose to water for reference fields. For photon beams, pulse repetition rate dependence, calibration stability, noise from the photodiode enclosure, detector motion during treatment, output factors, off-axis doses and percentage depth doses were tested. For electron and tomotherapy beams, energy non-dependence was verified. All features make the detector suitable in small and non-standards fields, and for electron beams.
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
20601 - Medical engineering
Result continuities
Project
<a href="/en/project/FV20411" target="_blank" >FV20411: Radiotherapy Treatment Planning System - the most advanced optimization algorithms for 3D dose calculation of external beams in the body and their integration into the new generation of the treatment planning system.</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Radiation protection dosimetry
ISSN
0144-8420
e-ISSN
1742-3406
Volume of the periodical
186
Issue of the periodical within the volume
2-3
Country of publishing house
GB - UNITED KINGDOM
Number of pages
6
Pages from-to
351-356
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-85082881633