Assessing 131I in thyroid by non-spectroscopic instruments - A European intercomparison exercise
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F19%3AN0000023" target="_blank" >RIV/86652052:_____/19:N0000023 - isvavai.cz</a>
Result on the web
<a href="https://www.sciencedirect.com/science/article/abs/pii/S1350448718307807" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S1350448718307807</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.radmeas.2019.04.018" target="_blank" >10.1016/j.radmeas.2019.04.018</a>
Alternative languages
Result language
angličtina
Original language name
Assessing 131I in thyroid by non-spectroscopic instruments - A European intercomparison exercise
Original language description
One of the issues of the Open Project for the European Radiation Research Area (OPERRA) was human thyroid monitoring in case of a large scale nuclear accident. This issue was covered in task 5.4 as project “CaThyMARA” (Child and Adult Thyroid Monitoring After Reactor Accident), which included several aspects of thyroid monitoring, e.g. screening of facilities able to perform thyroid monitoring in the European countries, dose estimation, modelling of detector response, and two intercomparison exercises. The intercomparison described in this paper focused on thyroid monitoring by non-spectrometric instruments, including gamma cameras and other instruments that were considered available for measurements made by members of the public. A total of 12 facilities from 7 European countries have participated and 43 various measuring devices have been evaluated. The main conclusion of this intercomparison is that the ability to make assessments of 131I activity in the thyroid to the exposed population after an accidental release must, on the average, be considered as good among the European laboratories taking part in this study. This intercomparison also gave the participants the possibility to calibrate the measuring devices for thyroid measurements of children where this procedure was not available before. A comprehensive report of the intercomparison is given.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10511 - Environmental sciences (social aspects to be 5.7)
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Radiation Measurements
ISSN
1350-4487
e-ISSN
—
Volume of the periodical
128
Issue of the periodical within the volume
September
Country of publishing house
GB - UNITED KINGDOM
Number of pages
6
Pages from-to
106115
UT code for WoS article
000497891200016
EID of the result in the Scopus database
2-s2.0-85061425457