All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

YAP:Ce Scintillator Application for 241Am Counting in Wound Injury

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F22%3AN0000009" target="_blank" >RIV/86652052:_____/22:N0000009 - isvavai.cz</a>

  • Result on the web

    <a href="https://academic.oup.com/rpd/article/198/9-11/586/6672985" target="_blank" >https://academic.oup.com/rpd/article/198/9-11/586/6672985</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1093/rpd/ncac102" target="_blank" >10.1093/rpd/ncac102</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    YAP:Ce Scintillator Application for 241Am Counting in Wound Injury

  • Original language description

    YAP:Ce scintillation probe was tested for use in a spectrometric measurement that is necessary to assess the internal dose in case of wound injuries involving radionuclide contaminant. A technique with metal filters published in the past for the determination of a depth of plutonium-contaminated wound was tested to verify the capability of the scintillator to be used for gamma-ray spectrometry counting of 241Am in a wound injury. Scintillation probe equipped with YAP:Ce scintillator showed properties sufficient for the wound counting technique tested.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10511 - Environmental sciences (social aspects to be 5.7)

Result continuities

  • Project

    <a href="/en/project/VI20192022136" target="_blank" >VI20192022136: Detector of the radioactive contamination in wounds</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Radiation Protection Dosimetry

  • ISSN

    0144-8420

  • e-ISSN

    1742-3406

  • Volume of the periodical

    198

  • Issue of the periodical within the volume

    9-11

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    4

  • Pages from-to

    586-589

  • UT code for WoS article

    000844405700016

  • EID of the result in the Scopus database