Result

Use of Directional Overcurrent Protection Scheme for Distributed Generation Systems

on adaptive directional overcurrent protections with inverse-time characteristics. First in protected system new protection setting is computed. Use of directional overcurrent protections with inverse...

Energy and fuels

  • 2015
  • D
Result

Protection settings optimization in distributed generation system

overcurrent protections with inverse-time characteristics, is performed. Next, validation for simulation of directional protections with inverse-time characteristics used in the model. a...

JE - Nejaderná energetika, spotřeba a užití energie

  • 2016
  • D
  • Link
Result

Adaptive Protection Scheme Used for Distributed Generation System Switched into Island Mode

This paper proposes setting algorithm for adaptive protection scheme based on directional overcurrent protections with inverse-time characteristics. Use example of the system. Advantage of protection scheme based o...

JE - Nejaderná energetika, spotřeba a užití energie

  • 2015
  • D
Result

Directional Overcurrent Relays Coordination Problems in Distributed Generation Systems

protection coordination based on directional overcurrent protections with inverse-time characteristics. The key question of protection coordination is the determination of correct values of all inverse-

Energy and fuels

  • 2017
  • Jimp
  • Link
Result

Nelder Mead Method Used in Protection Setting Optimization

The paper deals with distributed generation network protection based on adaptive directional overcurrent protections with inverse-time characteristics. Correct objective function. The shape of inverse-...

JE - Nejaderná energetika, spotřeba a užití energie

  • 2016
  • D
  • Link
Result

Instantaneous and Definite Time Overcurrent Protection Algorithms

The paper is focused on the instantaneous and definite time overcurrent protection algorithms. Overcurrent protection is one of the most used type of protection function. Algorithms are proposed according to IEC 60255-151. ...

JE - Nejaderná energetika, spotřeba a užití energie

  • 2015
  • D
Result

Development of protective functions and experimental verification after implementation into devices

Subject of the contract research was an over-current protection algorithms. It was the function of the instantaneous, time defined, inverse time, directional and non-directional over current protection. These protective fun...

JE - Nejaderná energetika, spotřeba a užití energie

  • 2015
  • Vsouhrn
Result

Optimal microgrid´s protection coordination considering N-1 contingency and optimum relay characteristics

’ directional overcurrent relays (DOCRs), which smartly selects the time-current characteristic of relays and considers all system topologies. Achieving an optimal protection the proposed smart selection ofstandard relay

Electrical and electronic engineering

  • 2021
  • Jimp
  • Link
Result

Thermal Models of Cables in Digital Protective Terminals

Certain sophisticated digital relays offer the possibility of protecting cables by means of a thermal model with parameter setting using the knowledge of the cable heating time constant and given operating conditions. The principle of the th...

JE - Nejaderná energetika, spotřeba a užití energie

  • 2008
  • Jx
Result

Cable Thermal Model in Protection System

Certain sophisticated digital relays offer the possibility of protecting cables by means of a thermal model with pa-rameter setting using the knowledge of the cable heating time constant and given operating conditions. The principle of the t...

JE - Nejaderná energetika, spotřeba a užití energie

  • 2008
  • D