Filters
BTL-08 Holter
ECG Holter ? 24 / 48 hour-run 2 / 3-channel monitor of ECG signal with storage of measured ECG signal to internal memory. Processing of measured ECG signal on the PC. Archiving of the ECG on the PC. Quick diagnosti...
FA - Kardiovaskulární nemoci včetně kardiochirurgie
- 2007 •
- Zpolop
Rok uplatnění
Zpolop - Poloprovoz
Emerging Role of Interleukin-1 in Cardiovascular Diseases
proinflammatory mediators and higher risk of cardiovascular events and pathologies. Likewise, some of the cardiovascular diseases lately appeared to have an autoimmune component. Interleukin-1 (IL-1), a master regulator of diverse ...
EB - Genetika a molekulární biologie
- 2009 •
- Jx
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
Measurement of Biosignals and Subsequent Processing for More Accurate Determination of Cardiovascular System Parameters
the condition of a patient's cardiovascular system. These parameters are derived from of measurement, so these signals are affected by different level of distortion and noise, or progression of cardiovascular system is qui...
JA - Elektronika a optoelektronika, elektrotechnika
- 2013 •
- D
Rok uplatnění
D - Stať ve sborníku
A Novel Seismocardiogram Mathematical Model for Simplified Adjustment of Adaptive Filter
of the main artefacts, their duration and acceleration. The resulting signal was processed filters to obtain optimal signal processing settings. Meanwhile, the optimal filter and reliable signal proce...
Electrical and electronic engineering
- 2022 •
- Jimp •
- Link
Rok uplatnění
Jimp - Článek v periodiku v databázi Web of Science
Výsledek na webu
Identification of Significant Features in Signals of Equine Cardiovascular System using ICA
Not available...
FS - Lékařská zařízení, přístroje a vybavení
- 2005 •
- D
Rok uplatnění
D - Stať ve sborníku
Environmental influence on variability of equine long-term ECG signal parameters
cardiovascular system performance. The equine cardiovascular system is greatly influence by its environment which influences ECG signal. For future work which studies the causes ofsudden equine dead we need to have suitabl...
FP - Ostatní lékařské obory
- 2002 •
- D
Rok uplatnění
D - Stať ve sborníku
CONDITIONS FOR MEASUREMENT OF EQUINE LONG-TERM ECG SIGNALS AND DETECTION OF RR AND QT INTERVALS ABSTRACT
cardiovascular system performance. The equine cardiovascular system is greatly influenced by its environment which influences ECG signal. For the work which primarily studies the causes of sudden cardiac death in horses we...
FS - Lékařská zařízení, přístroje a vybavení
- 2003 •
- D
Rok uplatnění
D - Stať ve sborníku
Cardioprotective role of the VIP signaling system
The review summarized actions of VIP and PACAP on cardiovascular system.
ED - Fyziologie
- 2005 •
- Jx
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
The Two Channels Complex Bioimpedance Signals in Cardiology
be achieved by processing all signals) and partly non-equivalent (different behaviour according to excitation of the cardiovascular system). The more detailed analysisThe complex bioimpedance signals measured in t...
FS - Lékařská zařízení, přístroje a vybavení
- 2006 •
- D
Rok uplatnění
D - Stať ve sborníku
Detection of Artifacts in Oscillometric Pulsations Signals
of the signal. For the proper processing of the signal it is very important to detect all artifacts precisely before signal processing. The paper deals with the methods of the cardiovascular syst...
JA - Elektronika a optoelektronika, elektrotechnika
- 2014 •
- D •
- Link
Rok uplatnění
D - Stať ve sborníku
Výsledek na webu
- 1 - 10 out of 197 843