Hygrothermal effects of leakages in ventilated roofs

The paper contains an overview of possibilities of CFD analysis of the effects of leakages on the behaviour of ventilated roofs.

JN - Stavebnictví

  • 2007
  • D
Result

The effects of leakages in roofs with ventilated air layers - a CFD approach

The paper is focused on hygrothermal behaviour of roofs with ventilated air layers subjected to air leakages in their internal decks. Possibilities of CFD of the paper includesa case study concerning various effects of leakages<...

JN - Stavebnictví

  • 2007
  • D
Result

The Effects of Leakages in Roofs with Ventilated Air Layers - a CFD Approach

The paper is focused on the possibilities of the CFD modelling of hygro-thermal behaviour of the roofs with ventilated air layers exposed to the leakages in their internal deck....

JN - Stavebnictví

  • 2008
  • Jx
Result

Sensory system for detection of water/liquid leakage in roof, insulation and pool systems

The utility model describe technical solution of wireless detection of leakage water/liquid through insulation in floor, roof or in swimming pools....

JB - Senzory, čidla, měření a regulace

  • 2016
  • Fuzit
  • Link
Result

ROOF LEAK DETECTION BY THERMOGRAPHY OF AS-BUILT BIM

The horizontal roofs of industrial buildings are the weakest part of a structure. Imperfect design of horizontal roofs causes roof leakage. For roofs with a large surface area, locating leakage po...

Civil engineering

  • 2022
  • D
  • Link
Result

Leakage into Green Roof in Consequence of Unsuitable Used Waterproofing

waterproofing in roof cladding is leakage into interiors of public building in Prague.Green roofs are used more often to roofing of buildings respect to their ecological priorities (they keep out dust and big quan...

JN - Stavebnictví

  • 2007
  • C
Result

Leakage into Underground Garages by Moveble Roof

thet thein ceiling is the load-bearing structure od green or moveble roof. In these CASE the leakage of moisture from roof-surface to interiére very often sets in. One such case is analysed in the following paper where the...

JN - Stavebnictví

  • 2002
  • Jx
Result

Leakage into Underground Garages in Prague

that their ceiling is the load-bearing structure of green or movable roof. In these cases the leakage of moisture from roof-surface to interior very often sets in. One such case is analysed in the following paper where the...

JN - Stavebnictví

  • 2012
  • D
Result

Failure analysis and rehabilitation of the roof cladding of the shopping center

Occurrences of flat roof failures on roof cladding, made in the period before renovation of the roofs of shopping centers. Remediation of these faults by a technically located directly under the roof, but especiall...

Civil engineering

  • 2018
  • O
Result

Rainwater Pipe

The invention is a new solution system leakage of water flowing from the sloping roofs into sewers or storm water tanks and more reliably and lower maintenance requirements than is necessary for the current state of technical soluti...

JN - Stavebnictví

  • 2014
  • P
  • Link