Filters
Sample preparation for measurement of hand X-ray fluorescence spectrometer, the measurement procedure and the determination of correction factors.
The content of certified methodology (working process) is the sample preparation for the measurement process by hand X-ray fluorescence spectrometer, custom measurement procedure, the procedure for determining the correction
DB - Geologie a mineralogie
- 2011 •
- O •
- Link
Rok uplatnění
O - Ostatní výsledky
Výsledek na webu
X-ray Micro Radiography Using Beam Hardening Correction
We present X-ray Micro Radiography Using Beam Hardening Correction...
BG - Jaderná, atomová a molekulová fyzika, urychlovače
- 2005 •
- A
Rok uplatnění
A - Audiovizuální tvorba
Cartridges for filters and their holders for X-ray tubes
The method of X-ray tomography makes it possible to image the internal it is advantageous to filter the polychromatic X-ray beam with a suitable material, very often for image data correction usin...
Applied mechanics
- 2024 •
- Gfunk
Rok uplatnění
Gfunk - Funkční vzorek
ToraBaC – TORATOM batch correction tool
ToraBaC is a software that is used for processing of tomographical images in a batch. It features a flat-field correction, or general calculation on the images with up to three images involved in the calculation. It is written in Python 3.7 ...
Electrical and electronic engineering
- 2020 •
- R •
- Link
Rok uplatnění
R - Software
Výsledek na webu
Beam Hardening Correction for X-ray radiography of soft biological samples
Correction of X-ray radiograms taken with semiconductor pixel detectors: The detection efficiency of pixels in semiconductor pixel detector is energy dependent it can perform correction of X-ray r...
BG - Jaderná, atomová a molekulová fyzika, urychlovače
- 2009 •
- R
Rok uplatnění
R - Software
Advanced X-ray radiography and tomography in several engineering applications
New developments in the fields of X-ray detectors, X-ray micro/nano sources and data processing bring new possibilities for engineering practice in many- and nano-focusX-ray tubes together with se...
JB - Senzory, čidla, měření a regulace
- 2011 •
- Jx •
- Link
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
Výsledek na webu
X-ray tube spectra measurement and correction using a CdTe detector and an analytic response matrix for photon energies up to 160 keV
measured with a spectrometry system consisting of the Amptek XR-100T X-ray of the corrected spectra were compared with the published and reference data. A fully satisfying quantitative correspondence was observed ...
FS - Lékařská zařízení, přístroje a vybavení
- 2016 •
- Jx •
- Link
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
Výsledek na webu
Fast and Automatic Skull Segmentation of Multidetector CT Head Images
This paper describes automatic and fast skull segmentation of head X-ray computed tomog-raphy (X-ray CT) images. Acquired data suffers from salient stair-step artifact which is corrected by regist...
JD - Využití počítačů, robotika a její aplikace
- 2012 •
- D
Rok uplatnění
D - Stať ve sborníku
An analytical X-ray CdTe detector response matrix for incomplete charge collection correction for energies up to 300 keV
by a Gauss function. The model was then used to correct experimentally measured X-ray used for X-ray spectra correction what suggests energy dependence of the phenomenonThe gamma and X-...
Nuclear physics
- 2018 •
- O •
- Link
Rok uplatnění
O - Ostatní výsledky
Výsledek na webu
An analytical X-ray CdTe detector response matrix for incomplete charge collection correction for photon energies up to 300 keV
. Application of the correction to measured X-ray spectra leads to quantitative and qualitative agreement of the measured corrected spectra with the theoretically calculated ones. The method was applied and verifie...
Nuclear physics
- 2018 •
- Jimp •
- Link
Rok uplatnění
Jimp - Článek v periodiku v databázi Web of Science
Výsledek na webu
- 1 - 10 out of 210 778