Filters
Optimization of measuring equipment with Flame Ionization Detector
Measurement of concentration field is a part of the gas dispersion experiments. Filed of concentration is formed by a model of terrain. Source of emission is placed in the model of terrain. The emission source produces tracer gas, which is being mixe...
BK - Mechanika tekutin
- 2006 •
- D
Rok uplatnění
D - Stať ve sborníku
Main Gas Chromatographic Detectors Used in Brewing Analytics
analytics the most frequently used gas chromatographic detectors are flame ionization detector (FID), electron capture detector (ECD), and flame photometric detector (FPD). This work is focused o...
CB - Analytická chemie, separace
- 2011 •
- Jx •
- Link
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
Výsledek na webu
Effect of detector temperature on the flame ionization detector response.
Annotation not available...
CB - Analytická chemie, separace
- 1994 •
- Jx
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
Determination of volatile organic compound in emission of stationary sources - comparison of on-line and manual methods
From comparative study of simultaneous on-line analysis of VOC's using a set of flame ionisation detectors follows that FID should not be generally used for this purpose due to improper performance characteristics....
EH - Ekologie – společenstva
- 2001 •
- D
Rok uplatnění
D - Stať ve sborníku
Cross-lingual Flames Detection in News Discussions
We introduce Flames Detector, an online system for measuring flames, i.e institutions or discussion moderators to detect news topics which evoke flames. We propose a machine learning approach to flames det...
Robotics and automatic control
- 2017 •
- D •
- Link
Rok uplatnění
D - Stať ve sborníku
Výsledek na webu
Analytical method for determination of volatile fatty acids in compost and also in other material of organic origin
Determination of volatile fatty acids is organized by injections of water phase in to gas chromatograph with flame-ionized detector. This method can be utilized for polar compounds, dissolved in water and very difficult for extracti...
DM - Tuhý odpad a jeho kontrola, recyklace
- 2009 •
- NmetC
Rok uplatnění
NmetC - Metodiky certifikované oprávněným orgánem
Study of gas dispersion around a 2D model hill in a boundary layer wind tunnel
Study of gas dispersion around a two-dimensional model hill was performed in a boundary layer wind in VZLU. A point emission source was built in the model hill surface and tracer gas concentration was measured using comb probe and flame ioni...
BK - Mechanika tekutin
- 2014 •
- D
Rok uplatnění
D - Stať ve sborníku
Experimental study of gas dispersion over complex terrain
Experimental study of gas dispersion over complex terrain model was performed in VZLU Prague. A complex terrain model was mounted into a boundary layer wind tunnel and equipped with ground-level gas emission source. Concentration field of the emitted...
BK - Mechanika tekutin
- 2015 •
- D •
- Link
Rok uplatnění
D - Stať ve sborníku
Výsledek na webu
Effect of boundary layer turbulence intensity on dispersion of gas emission of various buoyancy
The turbulence intensity in boundary layer wind tunnel influences gas dispersion with different buoyancy. The emission source was placed at floor level in the wind tunnel. Concentration field was measured using comb probe and flame ionisatio...
BK - Mechanika tekutin
- 2012 •
- D •
- Link
Rok uplatnění
D - Stať ve sborníku
Výsledek na webu
A novel method of furan determination in beer using gas chromatography with a flame ionization detector
and the film thickness of 0.25 µm was used for the determination of furan. A flame-ionization detector (FID) was used for the detection. The characteristics......
Analytical chemistry
- 2019 •
- Jimp •
- Link
Rok uplatnění
Jimp - Článek v periodiku v databázi Web of Science
Výsledek na webu
- 1 - 10 out of 16 281