Filters
Full-field measurements of large compressive deformations in human trabecular bone using digital volume correlation
Cylindrical sample of human trabecular bone has been incrementally compressed and its deformed microstructure captured using time-lapse microtomography. From the captured projections the deformed microstructure has been reconstructed and the displace...
FI - Traumatologie a ortopedie
- 2011 •
- D
Rok uplatnění
D - Stať ve sborníku
Tensile testing of 3D printed material with digital image correlation
on the digital image correlation (DIC) principles. It was concluded that in comparison of load curves and strain fields the support grid volume had a great effect sample volume filled by ribs, were tested for tens...
Mechanical engineering
- 2018 •
- D •
- Link
Rok uplatnění
D - Stať ve sborníku
Výsledek na webu
Precise strain measurement in complex materials using Digital Volumetric Correlation and time lapse micro-CT data
Digital volumetric correlation (DVC) method is employed for evaluation of full-volume displacement and strain fields in deformed material with complex microstructure such as trabecular bone and metal foam. Volumetric image ...
JJ - Ostatní materiály
- 2011 •
- O
Rok uplatnění
O - Ostatní výsledky
Digitally controlled physiological volume regulator
Physiological volume regulator with digital control permitting remote control...
JA - Elektronika a optoelektronika, elektrotechnika
- 2012 •
- Fuzit •
- Link
Rok uplatnění
Fuzit - Užitný vzor
Výsledek na webu
Evaluation of strain field in microstructures using micro-CT and digital volume correlation
X-ray digital micro-tomography was employed for precise strain measurement which is essential for evaluation of the experiments with small samples of trabecular bone. X-ray Digital Volumetric Correlation (DVC) method was us...
JJ - Ostatní materiály
- 2011 •
- Jx
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
Optical Measurement of the Elasticity Modulus using Digital Image Correlation
This paper presents the utilization of Digital Image Correlation Methodology for measuring of elasticity modulus in compression demonstrated on lime-mortar specimen. Benefits of Digital Image Correlation measuremen...
BH - Optika, masery a lasery
- 2008 •
- D
Rok uplatnění
D - Stať ve sborníku
Optimization and Calibration of Digital Image Correlation Method
An example of instrumentation and optimization of Digital Image Correlation measurement system for given class of experiments is described in this paper....
JB - Senzory, čidla, měření a regulace
- 2010 •
- D
Rok uplatnění
D - Stať ve sborníku
Compressive behaviour of trabecular tissue: finite element modelling and comparison using digital volume correlation
In this paper the deformation behaviour of the complex structure of a trabecular bone is investigated using the finite element (FE) simulation of a compression test. To obtain a geometrically accurate FE model of the trabecular microstructure and sui...
JJ - Ostatní materiály
- 2013 •
- D
Rok uplatnění
D - Stať ve sborníku
A digital design method for asphalt mixtures that incorporates aggregate geometry
This paper presents a new Data-Driven digital method for selecting aggregates of aggregates and volume of mastic (bitumen, filler, and aggregates with Min Feret < 2 mm) in a fixed 250 g of asphalt mixtures. The generated number of a...
Civil engineering
- 2024 •
- Jimp •
- Link
Rok uplatnění
Jimp - Článek v periodiku v databázi Web of Science
Výsledek na webu
Optical correlation scanner OKS
This device "Optical correlation scanner OKS" is established for precise close range spatial object point scanning based on image correlation technique by using motorised digital calibrated camera....
DE - Zemský magnetismus, geodesie, geografie
- 2009 •
- Gfunk •
- Link
Rok uplatnění
Gfunk - Funkční vzorek
Výsledek na webu
- 1 - 10 out of 76 062