Filters
Determination of volatile organic compound in emission of stationary sources - comparison of on-line and manual methods
From comparative study of simultaneous on-line analysis of VOC's using a set of flame ionisation detectors follows that FID should not be generally used for this purpose due to improper performance characteristics....
EH - Ekologie – společenstva
- 2001 •
- D
Rok uplatnění
D - Stať ve sborníku
Study of gas dispersion around a 2D model hill in a boundary layer wind tunnel
Study of gas dispersion around a two-dimensional model hill was performed in a boundary layer wind in VZLU. A point emission source was built in the model hill surface and tracer gas concentration was measured using comb probe and flame ...
BK - Mechanika tekutin
- 2014 •
- D
Rok uplatnění
D - Stať ve sborníku
Effect of boundary layer turbulence intensity on dispersion of gas emission of various buoyancy
The turbulence intensity in boundary layer wind tunnel influences gas dispersion with different buoyancy. The emission source was placed at floor level in the wind tunnel. Concentration field was measured using comb probe and flame ionis...
BK - Mechanika tekutin
- 2012 •
- D •
- Link
Rok uplatnění
D - Stať ve sborníku
Výsledek na webu
Reaction of Fatty Acid Methyl Ester with Monoethanolamine and Diethanolamine
The course of the reaction between lauric acid and monoethanolamine as well as the reaction of methyl laurate with monoethanolamine and diethanolamine were investigated. Thin layer chromatography with flame ionisation detector
Food and beverages
- 2021 •
- Jimp •
- Link
Rok uplatnění
Jimp - Článek v periodiku v databázi Web of Science
Výsledek na webu
Experimental study of gas dispersion over complex terrain
Experimental study of gas dispersion over complex terrain model was performed in VZLU Prague. A complex terrain model was mounted into a boundary layer wind tunnel and equipped with ground-level gas emission source. Concentration field of the emitted...
BK - Mechanika tekutin
- 2015 •
- D •
- Link
Rok uplatnění
D - Stať ve sborníku
Výsledek na webu
Gas dispersion modelling in a critical infrastructure area
with flame ionisation detectors.
Nuclear related engineering; (nuclear physics to be 1.3);
- 2018 •
- D •
- Link
Rok uplatnění
D - Stať ve sborníku
Výsledek na webu
Modular Preamplifier for Detectors of Ionising Radiation
The proposed preamplifier is dedicated to be used with ionising radiation detectors, especially with gaseous ionisation detectors and scintillation detectors and testing of future variants of preamplifiers...
Electrical and electronic engineering
- 2018 •
- Gfunk •
- Link
Rok uplatnění
Gfunk - Funkční vzorek
Výsledek na webu
Scintillation and Ionisation Detectors for Environmental SEM
We used a scintillation detector (YAG:Ce3+) on whose surface an electrode of an ionisation detector was created. As a specimen, two thin copper conductors were used between which a drop of plant oil was positioned....
JA - Elektronika a optoelektronika, elektrotechnika
- 1999 •
- Jx
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
Detection of Hazardous Radiation
The paper deals with detectors of hazardous radiation or ionising radiation. As hazardous radiation it is considered roentgen and gamma radiation. Firstly, detectors and the user. The paper in detail deals with group of
JA - Elektronika a optoelektronika, elektrotechnika
- 2011 •
- O
Rok uplatnění
O - Ostatní výsledky
Silicone Permation Estimation With use of Flame Ionisation Detector
By transport of some dangerous gases and liquids in chemical engineering is very important to detect a possible leak along the pipeline. The leak can be detected by a system which consists of special permeable detection pipeline placed very close to ...
JB - Senzory, čidla, měření a regulace
- 2008 •
- D
Rok uplatnění
D - Stať ve sborníku
- 1 - 10 out of 16 839