Result

Testing box for estimation of soil resistence against geotextile pulling out or estimation of shear strength of soil

press pulled geotextile out from soil. Measured are vertical pressure and force for geotextile pulling from different loading soil. Geotextile is placed into box on full plane of consolidated soil and it continues in slot ...

JN - Stavebnictví

  • 2010
  • Gfunk
Result

Bond Strength to Concrete through Pull-Out Tests of Epoxy-Coated Reinforcement

JN - Stavebnictví

  • 1998
  • X
Result

Testing apparatus for a screw insertion and its holding strength for orthopaedics.

Testing apparatus for a screw insertion with drilling and its uniaxial holding strength assessment for orthopaedics.

JQ - Strojní zařízení a nástroje

  • 2007
  • X
Result

Utilization of Waste Packaging Glass as Progressive Filler in Polymer Anchor Material Based on Epoxy Resin

strength, flexural strength, chemical resistance, shrinkage and pull-out test were anchor bolt pull-out strength. on epoxy resin, primarily for anchoring to a high strength conc...

Civil engineering

  • 2019
  • D
  • Link
Result

Assessment of Bond Behavior of UHPC and Prestressing Strands

, were tested in the laboratory. The specimens were prepared for pull out test, in which the prestressing strand is pulled out from the cube or part of girder made material with outstanding features (high compressi...

JN - Stavebnictví

  • 2014
  • D
  • Link
Result

Mechanical bond strength of ultralight concrete

This paper deals with comparison of mechanical bond strength calculated according to Standards and developed by pull-out tests. Mechanical bond strength was tested between reinforcement and ultralight concrete and ...

JN - Stavebnictví

  • 2014
  • D
Result

Pull-out test of non-metallic FRP reinforcement for concrete structures

A set of experiments for reinforcing concrete structures with FRP internal reinforcement consisting of pull-out tests of the system CFRP and GFRP bars with concrete according to ACI and Czech standrards and combined testing scheme (...

JN - Stavebnictví

  • 2006
  • D
Result

The effect of various test configurations on the bond strength of sand-coated GFRP bars

embedded in concrete. The bond strength was tested using ordinary centric pull-out tests (by ACI 440.3), modified pull-out tests with eccentrically placed bars also had a significant effect on bond st...

Construction engineering, Municipal and structural engineering

  • 2020
  • D
  • Link
Result

Corrosion Properties and Bond Strength of Coated (PE/PAK; PE/PPE; PAD) Reinforcement (B500B) with Normal Strength Concrete

pull-out test, the bond strength of such system was compared with bond strength of normal strength concrete (C30/37). Results of these tests show that key properties but simultaneously lower the bond ...

Civil engineering

  • 2022
  • C
  • Link
Result

Results of investigation into the behaviour of a grouted steel bolt abutment set on a laboratory physical model

mm. On prepared models of grouted steel bolt abutment there was done pull-out test to record the tensile pull-out force at bolt head and the displacements at two with regard to both scrutinized phenomena pull<...

JM - Inženýrské stavitelství

  • 2015
  • D
  • Link