Filters
The architectures of the systems for increased safety requirements
This paper deals with the structures and the architectures of the safety related systems. The assignment of architecture, which is related to the application of the system, belongs to one of the most important parts of the equipment design. ...
JA - Elektronika a optoelektronika, elektrotechnika
- 2016 •
- O
Rok uplatnění
O - Ostatní výsledky
Efficient use of multi-constellation EGNOS for the European Train Control System
) with the reactive fail-safetyarchitecture. The applicability of EGNOS V2 for the ETCS LDS railway safety standards has the potential to replace costly ETCS track-side balises and justification of the ETCS Virtual Balise (...
JW - Navigace, spojení, detekce a protiopatření
- 2016 •
- D
Rok uplatnění
D - Stať ve sborníku
Fail-Safe System Design
of the interlocking equipment is presented. The differences between fail-safe systems with inherent safety and fail-safe systems with redundant safety are described. The hypotheses for safety modelling ar...
JC - Počítačový hardware a software
- 2005 •
- D
Rok uplatnění
D - Stať ve sborníku
Fail-Safe System Architectures
This paper determines and discusses the hypotheses for safety modelling of fail-safe systems. The model of 2oo2 system is shown and described. The safety parameters of 2oo2 system are computed using this model....
JC - Počítačový hardware a software
- 2005 •
- D
Rok uplatnění
D - Stať ve sborníku
Functional approach on vehicle integrated safety assessment
The number of vehicle safety features has grown to large number of cooperative systems. As there exist assessment methods for passive safety systems, the need to offer relevant methods for active and integrated safety is ev...
Transport engineering
- 2011 •
- O •
- Link
Rok uplatnění
O - Ostatní výsledky
Výsledek na webu
Report by Problem of Assesment Rezidual Static Safety Panel Prefabricate Constructions with Account Influence of Stifness Vertikal Contact Failed by Crack
Report by Problem of Assesment Rezidual Static Safety Panel Prefabricate Constructions with Account Influence of Stifness Vertikal Contact Failed by Crack......
JN - Stavebnictví
- 2000 •
- D
Rok uplatnění
D - Stať ve sborníku
Comparison of Liquid and Gas Phase Plasma Reactors for Decolorization of Reactive Azo Dyes
Diaphragm discharge generated in liquids and water failing film dielectric barier discharge are compared as the plasma tools for decomposition of Direct Red 79 and Reactive Yellow 125 azo dyes. The specific energy density is calcula...
BL - Fyzika plasmatu a výboje v plynech
- 2014 •
- O
Rok uplatnění
O - Ostatní výsledky
Encapsulation of oxime K027 into cucurbit[7]uril: In vivo evaluation of safety, absorption, brain distribution and reactivation effectiveness
Oxime-based acetylcholinesterase reactivators (briefly oximes) regenerate paper focuses on cell toxicity, in vivo safety and influence of cucurbit[7]uril clearance. Contrary to the comparable in vitro reactivation power of ...
Toxicology
- 2020 •
- Jimp •
- Link
Rok uplatnění
Jimp - Článek v periodiku v databázi Web of Science
Výsledek na webu
Chronic antioxidant therapy fails to ameliorate hypertension: potential mechanisms behind
The elevated production of reactive oxygen species (ROS) is believed to play an important role in hypertension, but clinical studies on chronic antioxidant therapy of hypertension fail to confirm this hypothesis. Elevated ROS produc...
FA - Kardiovaskulární nemoci včetně kardiochirurgie
- 2009 •
- Jx
Rok uplatnění
Jx - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
The Reliability and Safety Computation for the Fault-tolerant and Fail-safe Systems
The Paper describes the dependability models for the fault-tolerant and fail-safe systems. The models for computation of the MTBF are shown for some railway interlocking equipments. The block and Markov models are used for the permanent beha...
JC - Počítačový hardware a software
- 2004 •
- D
Rok uplatnění
D - Stať ve sborníku
- 1 - 10 out of 38 450