All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Filters

178 791 (0,257s)

Result

Influence of Torso Model Accuracy on the Noninvasive Localization of Heart Pathologies

torso and heart model were used this error reached 3.4 cm and decreased to 1.0 cmThe influence of the fidelity of an inhomogeneous torso model were simulated in 7 CT-based realistic torso mod...

FS - Lékařská zařízení, přístroje a vybavení

  • 2013
  • Jx
  • Link
Result

Noninvasive Localization of Ectopic Activation Using BSPM and CT-Based Torso Model

activity in dependence on the used heart and torso model was examined. Best agreement the electrophysiological study was achieved when the CT-based torso and heart model was used. The use of a pe...

FA - Kardiovaskulární nemoci včetně kardiochirurgie

  • 2014
  • O
Result

Noninvasive localization of ectopic ventricular activity using BSPM and different patient torso models

activity and dependence of its accuracy on the used heart and torso model were examined and heart model based on whole-torso CT was used. The use of an individually adjusted general torso

FS - Lékařská zařízení, přístroje a vybavení

  • 2015
  • D
  • Link
Result

ECG Based Assessment of the Heart Position in Standard Torso Model

of vertical heart position in standard torso model, corresponding to the actual heart variability of the heart position in relation to the ecg lead V2 placed in the 4th intercostal level and considered as...

JD - Využití počítačů, robotika a její aplikace

  • 2011
  • D
Result

Assessment of heart position in a torso model using an inverse solution

of standard torso model in which the location of modeled heart is constant thus cannot position of heart in a standard torso model corresponding to the actual heart positionKnow...

JD - Využití počítačů, robotika a její aplikace

  • 2011
  • D
Result

Influence of Torso Model Complexity on the Noninvasive Localization of Ectopic Ventricular Activity

different torso models: homogeneous torso model, inhomogeneous torso model including lungs and heart ventricles and inhomogeneous torso model including lungs, heart...

FA - Kardiovaskulární nemoci včetně kardiochirurgie

  • 2016
  • Jx
  • Link
Result

Noninvasive identification of local disorders of electrogenesis in ventricular arrhythmias

different torso models: homogeneous torso model, torso model including the inhomogeneities of lungs and heart ventricles, and inhomogeneous torso model including lungs ...

Cardiac and Cardiovascular systems

  • 2017
  • JSC
  • Link
Result

Noninvasive identification of local disorders of electrogenesis in ventricular arrhythmias

different torso models: homogeneous torso model, torso model including the inhomogeneities of lungs and heart ventricles, and inhomogeneous torso model including lungs ...

Cardiac and Cardiovascular systems

  • 2017
  • JSC
  • Link
Result

Influence of Modeled Heart Cavities on the Noninvasive Localization of Ectopic Ventricular Activity

Noninvasive localization of premature ectopic ventricular activity was performed for four patients using integral body surface potential maps and inverse solution to one dipole. The influence of two different models of heart cavitie...

FA - Kardiovaskulární nemoci včetně kardiochirurgie

  • 2015
  • O
Result

First experience with PVC localization from clinical data

, and the patient specific torso model was created from whole torso CT scan. The position, homogeneous and inhomogeneous torso models. The inverse results for both cases were within the area of the PVC bea...

Cardiac and Cardiovascular systems

  • 2017
  • D
  • Link
  • 1 - 10 out of 178 791