New Laser Desorption Sample Introduction Techniques for Inductively Coupled Plasma Mass Spectrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216224%3A14740%2F13%3A00066032" target="_blank" >RIV/00216224:14740/13:00066032 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
New Laser Desorption Sample Introduction Techniques for Inductively Coupled Plasma Mass Spectrometry
Popis výsledku v původním jazyce
New techniques for determination of trace elements in submicroliter sample volumes, substrate-assisted laser desorption (SALD)1,2 and diode laser thermal vaporization (DLTV)3 inductively-coupled plasma mass spectrometry (ICP-MS) will be presented. In summary, the both SALD and DLTV ICP-MS are suitable for quantitative elemental analysis of low-volume samples (typically 100 ? 500 nL) and represent an alternative to nebulizers. Ad-vantages are also easy archiving, transportation, prearrangement of calibration sets and high through-put due to minimization of memory effects. In addition, biological samples, such as metalloproteins or metal complexes can be analyzed in other detection modes (MALDI-MS or fluorescence) from the same sample, which can providesupplementary information, e.g. protein mass or identity.
Název v anglickém jazyce
New Laser Desorption Sample Introduction Techniques for Inductively Coupled Plasma Mass Spectrometry
Popis výsledku anglicky
New techniques for determination of trace elements in submicroliter sample volumes, substrate-assisted laser desorption (SALD)1,2 and diode laser thermal vaporization (DLTV)3 inductively-coupled plasma mass spectrometry (ICP-MS) will be presented. In summary, the both SALD and DLTV ICP-MS are suitable for quantitative elemental analysis of low-volume samples (typically 100 ? 500 nL) and represent an alternative to nebulizers. Ad-vantages are also easy archiving, transportation, prearrangement of calibration sets and high through-put due to minimization of memory effects. In addition, biological samples, such as metalloproteins or metal complexes can be analyzed in other detection modes (MALDI-MS or fluorescence) from the same sample, which can providesupplementary information, e.g. protein mass or identity.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů