Nové přístupy v analýze obsahu steroidních estrogenů sedimentech
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F07%3A00019286" target="_blank" >RIV/60461373:22330/07:00019286 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Novel approaches to analysis of steroid estrogens in river sediments
Popis výsledku v původním jazyce
A wide range of estrogenic contaminants has been detected until now in the aquatic environment. Among them, natural and synthetic steroid estrogens, contained typically in municipal sewage treatment plant (STP) effluents, are in this respect the most potent chemicals. In our study, new GC/MS method has been developed for direct analysis of five major steroid estrogens (estrone, 17?-estradiol, 17?-ethinylestradiol, dienestrol and diethylstilbestrol) in river sediments. Four GC/MS systems employed for analysis of underivatized analytes in purified extracts were compared. Relatively low detection limits (1.5 - 5 ng/g dried sediment) and good repeatibility of GC splitless injections (RSD 1 - 2 %) were obtained in system employing low-pressure gas chromatography coupled to single quadrupole mass analyser (LP-GC/MS). The use of orthogonal gas chromatography (GCxGC) hyphenated with high-speed time-of-flight mass spectrometry (HSTOF-MS) enabled not only significantly better resolution of targe
Název v anglickém jazyce
Novel approaches to analysis of steroid estrogens in river sediments
Popis výsledku anglicky
A wide range of estrogenic contaminants has been detected until now in the aquatic environment. Among them, natural and synthetic steroid estrogens, contained typically in municipal sewage treatment plant (STP) effluents, are in this respect the most potent chemicals. In our study, new GC/MS method has been developed for direct analysis of five major steroid estrogens (estrone, 17?-estradiol, 17?-ethinylestradiol, dienestrol and diethylstilbestrol) in river sediments. Four GC/MS systems employed for analysis of underivatized analytes in purified extracts were compared. Relatively low detection limits (1.5 - 5 ng/g dried sediment) and good repeatibility of GC splitless injections (RSD 1 - 2 %) were obtained in system employing low-pressure gas chromatography coupled to single quadrupole mass analyser (LP-GC/MS). The use of orthogonal gas chromatography (GCxGC) hyphenated with high-speed time-of-flight mass spectrometry (HSTOF-MS) enabled not only significantly better resolution of targe
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical and Bioanalytical Chemistry
ISSN
1618-2642
e-ISSN
—
Svazek periodika
387
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
13
Strana od-do
1351-1363
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—