Feasibility of in-vivo simulation of acute hemodynamics in human atrial fibrillation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F16%3A00060082" target="_blank" >RIV/00023001:_____/16:00060082 - isvavai.cz</a>
Result on the web
<a href="http://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0165241&type=printable" target="_blank" >http://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0165241&type=printable</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1371/journal.pone.0165241" target="_blank" >10.1371/journal.pone.0165241</a>
Alternative languages
Result language
angličtina
Original language name
Feasibility of in-vivo simulation of acute hemodynamics in human atrial fibrillation
Original language description
This study evaluated hemodynamic feasibility and reproducibility of a new method for in vivo simulation of human atrial fibrillation (AF). The method was tested during sinus rhythm in 10 patients undergoing catheter ablation for AF. A simple electronic device was assembled that allowed triggering a cardiac stimulator by predefined series of RR intervals. Irregular RR interval sequences with a mean heart rate of 90/min and 130/min were obtained from ECG recordings of another patients with AF. Simultaneous atrioventricular pacing was delivered by catheters placed inside the coronary sinus and at the His bundle region. Hemodynamic effect of the simulated AF was assessed by invasive measurement of the left ventricular (LV) pressure, dP/dt, and Tau. Compared to regular pacing at the same mean heart rate, the simulated AF significantly impaired the LV both systolic and diastolic function. Repeated AF pacing in the same patients generated similar LV hemodynamics. The proposed method provides a realistic and reproducible in-vivo model of AF. It can be exploited for investigation of the hemodynamic consequences of AF in various patient populations.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FA - Cardiovascular diseases including cardio-surgery
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
PLoS ONE [online]
ISSN
1932-6203
e-ISSN
—
Volume of the periodical
11
Issue of the periodical within the volume
10
Country of publishing house
US - UNITED STATES
Number of pages
10
Pages from-to
"e0165241"
UT code for WoS article
000386204500138
EID of the result in the Scopus database
—