All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Mechanical intravascular hemolysis after percutaneous closure of perioaortal pseudoaneurysm

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F17%3A00076151" target="_blank" >RIV/00023001:_____/17:00076151 - isvavai.cz</a>

  • Result on the web

    <a href="https://ac.els-cdn.com/S0010865016301436/1-s2.0-S0010865016301436-main.pdf?_tid=be047d86-d449-11e7-8624-00000aab0f02&acdnat=1511880064_c3ba8e2269c5a8e8cecbe23e76a10331" target="_blank" >https://ac.els-cdn.com/S0010865016301436/1-s2.0-S0010865016301436-main.pdf?_tid=be047d86-d449-11e7-8624-00000aab0f02&acdnat=1511880064_c3ba8e2269c5a8e8cecbe23e76a10331</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.crvasa.2016.12.015" target="_blank" >10.1016/j.crvasa.2016.12.015</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Mechanical intravascular hemolysis after percutaneous closure of perioaortal pseudoaneurysm

  • Original language description

    Intravascular mechanical haemolysis may complicate the implantation of foreign materials into the bloodstream. This complication has been described most frequently with valve replacements, cardiac patches, or mechanical circulatory support devices. It appears to be exceptional in association with the implantation of occluders. In this work, we present a case of mechanical haemolysis induced by an Amplatzer occluder following the occlusion of a peri-aortic pseudoaneurysm.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30201 - Cardiac and Cardiovascular systems

Result continuities

  • Project

  • Continuities

    N - Vyzkumna aktivita podporovana z neverejnych zdroju

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Cor et vasa

  • ISSN

    0010-8650

  • e-ISSN

  • Volume of the periodical

    59

  • Issue of the periodical within the volume

    5

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    4

  • Pages from-to

    "E499"-"E502"

  • UT code for WoS article

    000413964700021

  • EID of the result in the Scopus database