All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

The European Registry for Patients with Mechanical Circulatory Support (EUROMACS) of the European Association for Cardio-Thoracic Surgery (EACTS): second report

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F18%3A00076529" target="_blank" >RIV/00023001:_____/18:00076529 - isvavai.cz</a>

  • Result on the web

    <a href="https://academic.oup.com/ejcts/article-abstract/53/2/309/4265538?redirectedFrom=PDF" target="_blank" >https://academic.oup.com/ejcts/article-abstract/53/2/309/4265538?redirectedFrom=PDF</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1093/ejcts/ezx320" target="_blank" >10.1093/ejcts/ezx320</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    The European Registry for Patients with Mechanical Circulatory Support (EUROMACS) of the European Association for Cardio-Thoracic Surgery (EACTS): second report

  • Original language description

    OBJECTIVES: The European Registry for Patients with Mechanical Circulatory Support (EUROMACS) was founded in Berlin, Germany. EUROMACS is supported fully by the European Association for Cardio-Thoracic Surgery (EACTS) and, since 2014, has functioned as a committee of the EACTS. The purpose of having the EUROMACS as a part of the EACTS is to accumulate clinical data related to long-term mechanical circulatory support for scientific purposes and to publish annual reports. RESULTS: Fifty-two hospitals participated in the registry. This report is based on 2947 registered implants in 2681 patients. Survival of adult patients (&gt;17 years of age) with continuous-flow left ventricular assist devices with a mean follow-up of 391 days was 69% (95% confidence interval 66-71%) 1 year after implantation. On average, patients were observed for 12 months (median 7 months, range 0-70 months). When we investigated for adverse events, we found an overall event rate per 100 patient-months of 3.56 for device malfunction, 6.45 for major bleeding, 6.18 for major infection and 3.03 for neurological events within the first 3 months after implantation. CONCLUSIONS: Compared to the first EUROMACS report, the number of participating hospitals increased from 21 to 52 (+148%), whereas the number of registered implants more than tripled from 825 to 2947 (+257%). The increase in the number of participating hospitals led us to increase the quality control measures through data input control, on-site audits and statistical analyses.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30201 - Cardiac and Cardiovascular systems

Result continuities

  • Project

  • Continuities

    N - Vyzkumna aktivita podporovana z neverejnych zdroju

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    European journal of cardio-thoracic surgery

  • ISSN

    1010-7940

  • e-ISSN

  • Volume of the periodical

    53

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    8

  • Pages from-to

    309-316

  • UT code for WoS article

    000424256500038

  • EID of the result in the Scopus database

    2-s2.0-85041536370