The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): third Paediatric (Paedi-EUROMACS) report
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F22%3A00083219" target="_blank" >RIV/00023001:_____/22:00083219 - isvavai.cz</a>
Result on the web
<a href="https://academic.oup.com/ejcts/article-abstract/62/2/ezac355/6618527?redirectedFrom=fulltext&login=true" target="_blank" >https://academic.oup.com/ejcts/article-abstract/62/2/ezac355/6618527?redirectedFrom=fulltext&login=true</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/ejcts/ezac355" target="_blank" >10.1093/ejcts/ezac355</a>
Alternative languages
Result language
angličtina
Original language name
The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): third Paediatric (Paedi-EUROMACS) report
Original language description
OBJECTIVES A third paediatric report has been generated from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). The purpose of EUROMACS, which is operated by the European Association for Cardio-Thoracic Surgery, is to gather data related to durable mechanical circulatory support for scientific purposes and to publish reports with respect to the course of mechanical circulatory support therapy. Since the first report issued, efforts to increase compliance and participation have been extended. Additionally, the data provided the opportunity to analyse patients of younger age and lower weight. METHODS Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (<19 years of age) performed from 1 January 2000 to 31 December 2020 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events including neurological dysfunction, device malfunction, major infection and bleeding. RESULTS Twenty-five hospitals contributed 537 registered implants in 480 patients. The most frequent aetiology of heart failure was any form of cardiomyopathy (59%), followed by congenital heart disease and myocarditis (15% and 14%, respectively). Competing outcomes analysis revealed that a total of 86% survived to transplant or recovery or are ongoing; at the 2-year follow-up examination, 21.9% died while on support. At 12 months, 45.1% received transplants, 7.5% were weaned from their device and 20.8% died. The 3-month adverse events rate was 1.59 per patient-year for device malfunction including pump exchange, 0.7 for major bleeding, 0.78 for major infection and 0.71 for neurological events. CONCLUSIONS The overall survival rate was 79.2% at 12 months following ventricular assist device implant. The comparison of survival rates of the early and later eras shows no significant difference. A focus on specific subgroups showed that survival was less in patients of younger age (<1 year of age; P = 0.01) and lower weight (<20 kg; P = 0.015). Transplant rates at 6 months continue to be low (33.2%). The lack of European registration on durable mechanical circulatory support (MCS) led to the foundation of European Registry for Patients with Mechanical Circulatory Support (EUROMACS) in 2009.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
European journal of cardio-thoracic surgery
ISSN
1010-7940
e-ISSN
1873-734X
Volume of the periodical
62
Issue of the periodical within the volume
2
Country of publishing house
GB - UNITED KINGDOM
Number of pages
9
Pages from-to
"Art. no. ezac355"
UT code for WoS article
000822875300003
EID of the result in the Scopus database
2-s2.0-85134426516