All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Implantable cardioverter-defibrillator therapy in hypertrophic cardiomyopathy: A SIMPLE substudy

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F18%3A00076548" target="_blank" >RIV/00023001:_____/18:00076548 - isvavai.cz</a>

  • Result on the web

    <a href="http://www.heartrhythmjournal.com/article/S1547-5271(17)31360-7/pdf" target="_blank" >http://www.heartrhythmjournal.com/article/S1547-5271(17)31360-7/pdf</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.hrthm.2017.11.020" target="_blank" >10.1016/j.hrthm.2017.11.020</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Implantable cardioverter-defibrillator therapy in hypertrophic cardiomyopathy: A SIMPLE substudy

  • Original language description

    BACKGROUND Patients with hypertrophic cardiomyopathy (HCM) are considered to be at high risk for elevated defibrillation thresholds, periprocedural complications, and failed appropriate shocks. OBJECTIVE The purpose of this study was to determine the value of defibrillation testing (DT) in HCM patients undergoing implantable cardioverter-defibrillator (ICD) insertion. METHODS Defibrillation thresholds, perioperative complications, and long-term outcomes were compared between patients with HCM and those with ischemic cardiomyopathy (ICM) or dilated cardiomyopathy (DCM) enrolled in the SIMPLE (Shockless IMPLant Evaluation) trial (Clinialtrials.gov Identifier: NCT00800384). In patients with HCM, outcomes were also compared between those randomized to DT vs no DT. RESULTS Adequate defibrillation safety margin without system change was achieved in 46 of 52 (88.5%) HCM and 948 of 1047 (90.5%) ICM/DCM patients (P = .63). Perioperative complications occurred in 1 of 52 (1.9%) HCM patients with DT compared to 67 of 1047 (6.4%) ICM/DCM patients with DT (P = .37) or 3 of 42 (7.1%) HCM patients without DT (P = .32). During follow-up, there was no significant difference between HCM vs ICM/DCM patients in terms of all-cause mortality (adjusted hazard ratio [HR] 1.02, 95% confidence interval [CI] 0.45-2.34), composite of arrhythmic death or failed appropriate shock (adjusted HR 0.33, 95% CI 0.04-2.42), inappropriate shocks (adjusted HR 1.64, 95% CI 0.69-3.89), or system complications (adjusted HR 1.93, 95% CI 0.88-4.27). All-cause mortality (HR 0.26, 95% CI 0.03-2.20), appropriate (HR 0.24, 95% CI 0.03-2.05), and inappropriate shocks (HR 2.13, 95% CI 0.51-8.94) were similar in HCM patients without or those with DT. CONCLUSION We did not find any difference in intraoperative defibrillation efficacy, perioperative complications, and long-term outcomes between patients with HCM and those with ICM/DCM. DT did not improve intraoperative or clinical shock efficacy in HCM patients.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30201 - Cardiac and Cardiovascular systems

Result continuities

  • Project

  • Continuities

    N - Vyzkumna aktivita podporovana z neverejnych zdroju

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Heart rhythm

  • ISSN

    1547-5271

  • e-ISSN

  • Volume of the periodical

    15

  • Issue of the periodical within the volume

    3

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    7

  • Pages from-to

    386-392

  • UT code for WoS article

    000426467700015

  • EID of the result in the Scopus database

    2-s2.0-85041575430