Accuracy of electroanatomical mapping-guided cardiac radiotherapy for ventricular tachycardia: pitfalls and solutions
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F21%3A00081944" target="_blank" >RIV/00023001:_____/21:00081944 - isvavai.cz</a>
Alternative codes found
RIV/00843989:_____/21:E0109287 RIV/00216208:11110/21:10435617
Result on the web
<a href="https://academic.oup.com/europace/article/23/12/1989/6370658" target="_blank" >https://academic.oup.com/europace/article/23/12/1989/6370658</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/europace/euab195" target="_blank" >10.1093/europace/euab195</a>
Alternative languages
Result language
angličtina
Original language name
Accuracy of electroanatomical mapping-guided cardiac radiotherapy for ventricular tachycardia: pitfalls and solutions
Original language description
Aims To analyse and optimize the interobserver agreement for gross target volume (GTV) delineation on cardiac computed tomography (CCT) based on electroanatomical mapping (EAM) data acquired to guide radiotherapy for ventricular tachycardia (VT). Methods and results Electroanatomical mapping data were exported and merged with the segmented CCT using manual registration by two observers. A GTV was created by both observers for predefined left ventricular (LV) areas based on preselected endocardial EAM points indicating a two-dimensional (2D) surface area of interest. The influence of (interobserver) registration accuracy and availability of EAM data on the final GTV and 2D surface location within each LV area was evaluated. The median distance between the CCT and EAM after registration was 2.7 mm, 95th percentile 6.2 mm for observer #1 and 3.0 mm, 95th percentile 7.6 mm for observer #2 (P = 0.9). Created GTVs were significantly different (8 vs. 19 mL) with lowest GTV overlap (35%) for lateral wall target areas. Similarly, the highest shift between 2D surfaces was observed for the septal LV (6.4 mm). The optimal surface registration accuracy (2.6 mm) and interobserver agreement (A interobserver EAM surface registration 1.3 mm) was achieved if at least three cardiac chambers were mapped, including high-quality endocardial LV EAM. Conclusion Detailed EAM of at least three chambers allows for accurate co-registration of EAM data with CCT and high interobserver agreement to guide radiotherapy of VT. However, the substrate location should be taken in consideration when creating a treatment volume margin. [GRAPHICS] .
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
<a href="/en/project/NU20-02-00244" target="_blank" >NU20-02-00244: STereotactic Ablative Radiosurgery of recurrent Ventricular Tachycardia in structural heart disease</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Europace
ISSN
1099-5129
e-ISSN
—
Volume of the periodical
23
Issue of the periodical within the volume
12
Country of publishing house
GB - UNITED KINGDOM
Number of pages
9
Pages from-to
1989-1997
UT code for WoS article
000733371300014
EID of the result in the Scopus database
2-s2.0-85122186404