Efficacy and safety of focal pulsed-field ablation for ventricular arrhythmias: two-centre experience

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F24%3A00084949" target="_blank" >RIV/00023001:_____/24:00084949 - isvavai.cz</a>

  • Alternative codes found

    RIV/60076658:12110/24:43908587

  • Result on the web

    <a href="https://academic.oup.com/europace/article/26/7/euae192/7710820?login=true" target="_blank" >https://academic.oup.com/europace/article/26/7/euae192/7710820?login=true</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1093/europace/euae192" target="_blank" >10.1093/europace/euae192</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Efficacy and safety of focal pulsed-field ablation for ventricular arrhythmias: two-centre experience

  • Original language description

    Aims A pulsed electric field (PF) energy source is a novel potential option for catheter ablation of ventricular arrhythmias (VAs) as it can create deeper lesions, particularly in scarred tissue. However, very limited data exist on its efficacy and safety. This prospective observational study reports the initial experience with VA ablation using focal PF.Methods and results The study population consisted of 44 patients (16 women, aged 61 +/- 14years) with either frequent ventricular premature complexes (VPCs, 48%) or scar-related ventricular tachycardia (VT, 52%). Ablation was performed using an irrigated 4 mm tip catheter and a commercially available PF generator. On average, 16 +/- 15 PF applications (25 A) were delivered per patient. Acute success was achieved in 84% of patients as assessed by elimination of VPC or reaching non-inducibility of VT. In three cases (7%), a transient conduction system block was observed during PF applications remotely from the septum. Root analysis revealed that this event was caused by current leakage from the proximal shaft electrodes in contact with the basal interventricular septum. Acute elimination of VPC was achieved in 81% patients and non-inducibility of VT in 83% patients. At the 3-month follow-up, persistent suppression of the VPC was confirmed on Holter monitoring in 81% patients. In the VT group, the mean follow-up was 116 +/- 75 days and a total of 52% patients remained free of any VA.Conclusion Pulsed electric field catheter ablation of a broad spectrum of VA is feasible with acute high efficacy; however, the short-term follow-up is less satisfactory for patients with scar-related VT. Graphical Abstract

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30201 - Cardiac and Cardiovascular systems

Result continuities

  • Project

    <a href="/en/project/LX22NPO5104" target="_blank" >LX22NPO5104: National Institute for Research of Metabolic and Cardiovascular Diseases</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2024

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Europace

  • ISSN

    1099-5129

  • e-ISSN

    1532-2092

  • Volume of the periodical

    26

  • Issue of the periodical within the volume

    7

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    8

  • Pages from-to

    "art. no. euae192"

  • UT code for WoS article

    001274847000002

  • EID of the result in the Scopus database

    2-s2.0-85199689929