Acute durability of cavotricuspid isthmus block after pulsed electric field ablation: randomized comparison of two pentaspline catheter configurations (SECTION trial)
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F25%3A00085887" target="_blank" >RIV/00023001:_____/25:00085887 - isvavai.cz</a>
Alternative codes found
RIV/60076658:12110/25:43910522 RIV/61988987:17110/25:A2603DG7 RIV/00216208:11110/25:10503232 RIV/00216208:11130/25:10503232 RIV/00064165:_____/25:10503232
Result on the web
<a href="https://academic.oup.com/europace/article/27/10/euaf234/8262584" target="_blank" >https://academic.oup.com/europace/article/27/10/euaf234/8262584</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/europace/euaf234" target="_blank" >10.1093/europace/euaf234</a>
Alternative languages
Result language
angličtina
Original language name
Acute durability of cavotricuspid isthmus block after pulsed electric field ablation: randomized comparison of two pentaspline catheter configurations (SECTION trial)
Original language description
Aims: Cavotricuspid isthmus (CTI) ablation is commonly performed alongside catheter ablation of atrial fibrillation (AF). However, the acute efficacy of the CTI ablation using the pentaspline catheter and pulsed electric field (PEF) energy has not been systematically evaluated. This randomized study assessed the acute efficacy and extent of haemolysis associated with CTI ablation when performed using two different configurations of the pentaspline catheter. Methods and results: A total of 178 patients (age 65 +/- 10 years, 66% of males) undergoing PEF ablation of the CTI in conjunction with AF ablation were randomly assigned to receive ablation using either the basket configuration (n = 95) or the flower configuration (n = 83) of the pentaspline catheter. The CTI ablation was performed before left atrial ablation. It was guided by intracardiac echocardiography, and bidirectional block was confirmed by pacing manoeuvres. Venous blood samples to assess haemolytic biomarkers were collected before and immediately after the CTI ablation. The groups were broadly comparable in baseline characteristics. The flower group demonstrated superior procedural efficiency, with fewer applications required to achieve a CTI block (3.4 +/- 3.1 vs. 8.0 +/- 4.1, P < 0.001), a shorter time to block (96 +/- 289 vs. 177 +/- 192 s, P < 0.001), and fewer total applications (10.1 +/- 3.4 vs. 13.3 +/- 5.1, P < 0.001). Acute reconduction occurred in 20% of cases overall, but was significantly lower in the flower group (6% vs. 32%, P < 0.001; hazard ratio: 0.14, 95% confidence interval: 0.06-0.40). Haemolysis was notably lower in the flower group, with significantly less post-procedural free haemoglobin (154 +/- 112 vs. 210 +/- 115 mg/L, P < 0.001). One case of transient ST elevations occurred in the flower group without clinical consequence. Conclusion: Pulsed electric field ablation of the CTI using the flower configuration of the pentaspline catheter demonstrated higher acute efficacy in achieving CTI block and a more favourable safety profile regarding haemolysis compared to the basket configuration. This is likely due to the larger footprint and improved tissue contact of all electrodes, minimizing the leakage of PEF energy into the blood pool. [GRAPHICS]
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
<a href="/en/project/LX22NPO5104" target="_blank" >LX22NPO5104: National Institute for Research of Metabolic and Cardiovascular Diseases</a><br>
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Europace
ISSN
1099-5129
e-ISSN
1532-2092
Volume of the periodical
27
Issue of the periodical within the volume
10
Country of publishing house
GB - UNITED KINGDOM
Number of pages
9
Pages from-to
"art. no. euaf234"
UT code for WoS article
001591064500001
EID of the result in the Scopus database
2-s2.0-105018344824