All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Quantification of artifacts during cardiac magnetic resonance in patients with leadless Micra pacemakers

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F21%3A00009062" target="_blank" >RIV/00023884:_____/21:00009062 - isvavai.cz</a>

  • Result on the web

    <a href="https://pubmed.ncbi.nlm.nih.gov/33682228/" target="_blank" >https://pubmed.ncbi.nlm.nih.gov/33682228/</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1111/jce.14988" target="_blank" >10.1111/jce.14988</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Quantification of artifacts during cardiac magnetic resonance in patients with leadless Micra pacemakers

  • Original language description

    Introduction When cardiac magnetic resonance (MR) is performed after previous leadless transcatheter pacemaker implantation, an image distortion has to be expected in the heart region and evaluation of myocardial tissue can be affected. In this clinical prospective study, we aim to assess the extent and impact of this artifact on individual ventricular segments and compare it to conventional pacing devices. Methods Total of 20 patients with leadless pacemaker placed in the right ventricle underwent cardiac MR imaging in a 1.5 Tesla scanner. A multiplanar segmentation was used to demarcate the left and right ventricular myocardium as well as the pacemaker-caused image artifact in systolic and diastolic time frames. Artifact size and its relative influence on myocardial segments were quantitatively assessed and expressed in AHA-17 model. Results Implanted leadless pacemaker caused an image artifact with a volume of 48 +/- 5 ml. Most distorted were the apical septal (53 +/- 23%), apical inferior (30 +/- 18%), and midventricular inferoseptal (30 +/- 20%) segments. The artifact intersection with basal and lateral segments was none or negligible (up to 2%). The portion of left ventricular (LV) myocardium affected by the artifact was significantly higher in systole (8 +/- 4%) compared to diastole (10 +/- 3%; p < .001). Conclusion Implantation of leadless pacemaker represents no obstacle for cardiac MR imaging but causes an image artifact located mostly in septal, inferoseptal, and anteroseptal segments of apical and midventricular LV myocardium. With the exception of the apex, diastolic timing reduces the image distortion of all segments and improves global ventricular assessment.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30201 - Cardiac and Cardiovascular systems

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2021

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Cardiovascular Electrophysiology

  • ISSN

    1045-3873

  • e-ISSN

  • Volume of the periodical

    32

  • Issue of the periodical within the volume

    5

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    9

  • Pages from-to

    1367-1375

  • UT code for WoS article

    000632681800001

  • EID of the result in the Scopus database

    2-s2.0-85103203154