Intracardiac Echocardiography-Guided Left Atrial Appendage Closure With a Novel Foam-Based Conformable Device: Safety and 1-Year Outcomes
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F22%3A00009435" target="_blank" >RIV/00023884:_____/22:00009435 - isvavai.cz</a>
Result on the web
<a href="https://www-sciencedirect-com.ezproxy.lib.cas.cz/science/article/abs/pii/S2405500X21008537?via%3Dihub" target="_blank" >https://www-sciencedirect-com.ezproxy.lib.cas.cz/science/article/abs/pii/S2405500X21008537?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jacep.2021.10.001" target="_blank" >10.1016/j.jacep.2021.10.001</a>
Alternative languages
Result language
angličtina
Original language name
Intracardiac Echocardiography-Guided Left Atrial Appendage Closure With a Novel Foam-Based Conformable Device: Safety and 1-Year Outcomes
Original language description
OBJECTIVES This is a first report of the safety and 1-year outcomes of left atrial appendage closure (LAAC) using a novel foam-based conformable device, guided by intracardiac echocardiography (ICE). BACKGROUND Limitations of current transcatheter LAAC devices include the need for precise coaxial delivery into the left atrial appendage (LAA), potential for traumatic implantation, incomplete LAA seal, and device-related thrombus. METHODS The device (Conformal Left Atrial Appendage Seal, Conformal Medical Inc) is a self-expanding occluder consisting of a cylindrical nitinol endoskeleton with low-profile anchor barbs around the midpoint, covered with a porous foam cup. In a prospective single-center series, under conscious sedation, the device was delivered under fluoroscopic and ICE guidance. After positioning, a transesophageal echocardiography probe was placed to confirm ICE findings before device release. After closure, dual antiplatelet therapy was administered for 6 months. Follow-up imaging was planned for 45 days and 6 and 12 months. RESULTS A total of 15 patients (age 71.3 +/- 10.8 years, 33% men, CHA2DS2-VASc 4.1 +/- 1.7, HAS-BLED 3.4 +/- 1.4) underwent LAAC, 100% successfully. There were no procedure/device-related complications requiring intervention. Asymptomatic pericardial effusion occurred in 2 patients. The 45-day, 6-month, and 12-month follow-up imaging in 11, 9, and 13 patients, respectively, revealed adequate LAA seal (leak #5 mm) in all patients; device-related thrombus was detected in 1 patient at 6 months. Over 1-year follow-up, there were no ischemic strokes and 1 minor bleed. Nonprocedure-/device-related death occurred in 2 patients. CONCLUSIONS This first report indicates that LAAC with the conformable implant guided by ICE imaging is feasible with encouraging 1-year clinical outcomes. (C) 2022 Published by Elsevier on behalf of the American College of Cardiology Foundation.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30105 - Physiology (including cytology)
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
JACC: Clinical Electrophysiology
ISSN
2405-500X
e-ISSN
—
Volume of the periodical
8
Issue of the periodical within the volume
2
Country of publishing house
US - UNITED STATES
Number of pages
11
Pages from-to
197-207
UT code for WoS article
000760853000009
EID of the result in the Scopus database
2-s2.0-85124463496