All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Fetal Dose Evaluation for Pregnant Patients on Leksell Gamma Knife Perfexion/Icon

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F24%3A00009624" target="_blank" >RIV/00023884:_____/24:00009624 - isvavai.cz</a>

  • Result on the web

    <a href="https://karger.com/sfn/article-abstract/102/2/65/893970/Fetal-Dose-Evaluation-for-Pregnant-Patients-on?redirectedFrom=fulltext" target="_blank" >https://karger.com/sfn/article-abstract/102/2/65/893970/Fetal-Dose-Evaluation-for-Pregnant-Patients-on?redirectedFrom=fulltext</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1159/000535366" target="_blank" >10.1159/000535366</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Fetal Dose Evaluation for Pregnant Patients on Leksell Gamma Knife Perfexion/Icon

  • Original language description

    It is a normal procedure to avoid the application of ionizing radiation during pregnancy. In very rare occasions treatment can be performed but doses to the fetus must be evaluated and reported and the patient must sign informed consent. There can occur two types of damage caused by ionizing radiation – deterministic and stochastic effects. Deterministic effects may occur after reaching a certain threshold (100 mGy for this study), meanwhile, stochastic effects have no limit and their probability rises with dose. This study focuses on deterministic effects. This study compares the dose measured on phantom for the area of the pelvis and the dose measured on 3 patients with dosimeters positioned on the pelvis irradiated on Leksell Gamma Knife Perfexion/Icon. The mean dose for measurement on phantom for pelvis was 0.73 ± 0.76 mGy and for patients, it was 1.28 mGy, 0.493 mGy, 0.549 mGy which is 80 times lower, 200 times lower, 180 times lower than the threshold for deterministic effects, respectively. The measurement carried on phantom served as the base for drafting informed consent and provided initial proof that treatment can be safely delivered. Measurements performed on patients only confirmed that irradiation of pregnant patients on Leksell Gamma Knife Perfexion/Icon is safe relative to the deterministic effects. Nevertheless, pregnant patients should be treated with ionizing radiation only in very extraordinary situations.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30103 - Neurosciences (including psychophysiology)

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2024

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Stereotactic and Functional Neurosurgery

  • ISSN

    1011-6125

  • e-ISSN

  • Volume of the periodical

    102

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    9

  • Pages from-to

    65-73

  • UT code for WoS article

    001164053200001

  • EID of the result in the Scopus database

    2-s2.0-85182552454