Noninvasive Assessment of Aortic Pulse Wave Velocity by the Brachial Occlusion-Cuff Technique: Comparative Study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F19%3A10400542" target="_blank" >RIV/00064165:_____/19:10400542 - isvavai.cz</a>
Alternative codes found
RIV/68407700:21230/19:00332373 RIV/68407700:21730/19:00332373 RIV/00216208:11110/19:10400542
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=xLhcnMaurb" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=xLhcnMaurb</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/s19163467" target="_blank" >10.3390/s19163467</a>
Alternative languages
Result language
angličtina
Original language name
Noninvasive Assessment of Aortic Pulse Wave Velocity by the Brachial Occlusion-Cuff Technique: Comparative Study
Original language description
Cardiovascular diseases are one of most frequent cause of morbidity and mortality in the world. There is an emerging need for integrated, non-invasive, and easy-to-use clinical tools to assess accurately cardiovascular system primarily in the preventative medicine. We present a novel design for a non-invasive pulse wave velocity (PWV) assessment method integrated in a single brachial blood pressure monitor allowing for up to 100 times more sensitive recording of the pressure pulsations based on a brachial occlusion-cuff (suprasystolic) principle. The monitor prototype with built-in proprietary method was validated with a gold standard reference technique SphygmoCor VX device. The blood pressure and PWV were assessed on twenty-five healthy individuals (9 women, age (37 +/- 13) years) in a supine position at rest by a brachial cuff blood pressure monitor prototype, and immediately re-tested using a gold standard method. PWV using our BP monitor was (6.67 +/- 0.96) m/s compared to PWV determined by SphygmoCor VX (6.15 +/- 1.01) m/s. The correlation between methods using a Pearson's correlation coefficient was r = 0.88 (p < 0.001). The study demonstrates the feasibility of using a single brachial cuff build-in technique for the assessment of the arterial stiffness from a single ambulatory blood pressure assessment.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
<a href="/en/project/TH04010173" target="_blank" >TH04010173: Apparatus for non-invasive automatic analysis of hemodynamic parameters</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Sensors
ISSN
1424-8220
e-ISSN
—
Volume of the periodical
19
Issue of the periodical within the volume
16
Country of publishing house
CH - SWITZERLAND
Number of pages
10
Pages from-to
3467
UT code for WoS article
000484407200024
EID of the result in the Scopus database
2-s2.0-85071281726