New Ways of Non-invasive Measuring of Blood Circulation Parameters
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F10%3APU86131" target="_blank" >RIV/00216305:26220/10:PU86131 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
New Ways of Non-invasive Measuring of Blood Circulation Parameters
Original language description
The purpose of the article is to describe possible ways of non-invasive measuring and analysis of blood circulation parameters. These parameters are very important indicators of various cardiovascular diseases in clinical practice. For this purpose, methods of purely non-invasive analysis are sought. A standard approach is to use an inflatable cuff for blood pressure monitoring and analysis, using different methods of measuring, typically systolic, diastolic, mean and, less commonly, continuous blood pressure values. Inflatable cuff is a device decrementing a patient's comfort, namely by long-time (24 and more hours) monitoring. In this article, three principles of purely non-invasive (without inflatable cuff) measurement are described together with some experimental results. The first method described is based on a reliable detection of artery sectional area in the video sequence of B-mode ultrasound images using the Lucas-Canade optical flow determination technique. The output of thi
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
JA - Electronics and optoelectronics
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/2B06111" target="_blank" >2B06111: New Diagnostic Methods of Circulatory System Parameters Recognition Based on Infra-Red Scanning of Blood-Vessels Image.</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2010
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
WSEAS Transactions on Signal Processing
ISSN
1790-5052
e-ISSN
—
Volume of the periodical
2010
Issue of the periodical within the volume
6
Country of publishing house
GR - GREECE
Number of pages
11
Pages from-to
—
UT code for WoS article
—
EID of the result in the Scopus database
—