Diffuse Reflectance Spectroscopy as a Novel Method of Caries Detection—An In Vitro Comparative Study in Permanent Teeth
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F23%3A10464788" target="_blank" >RIV/00064165:_____/23:10464788 - isvavai.cz</a>
Alternative codes found
RIV/68407700:21730/23:00371379 RIV/00216208:11110/23:10464788 RIV/60461373:22340/23:43927703
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=3JGRQGa7EJ" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=3JGRQGa7EJ</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/diagnostics13111878" target="_blank" >10.3390/diagnostics13111878</a>
Alternative languages
Result language
angličtina
Original language name
Diffuse Reflectance Spectroscopy as a Novel Method of Caries Detection—An In Vitro Comparative Study in Permanent Teeth
Original language description
This in vitro study aimed to compare outcomes of dental caries detection using visual inspection classified according to the International Caries Detection and Assessment System (ICDAS) with objective assessments using a well-established laser fluorescence system (Diagnodent pen) and a novel diffuse reflectance spectroscopy (DRS) device. One hundred extracted permanent premolars and molars were utilized, including sound teeth, teeth with non-cavitated caries, or teeth with small cavitated lesions. A total of 300 regions of interest (ROIs) were assessed using each detection method. Visual inspection, being a subjective method, was performed by two independent examiners. The presence and extent of caries were histologically verified according to Downer's criteria, serving as a reference for other detection methods. Histological results revealed 180 sound ROIs and 120 carious ROIs, categorized into three different extents of caries. Overall, there was no significant difference between the detection methods in sensitivity (0.90-0.93) and false negative rate (0.05-0.07). However, DRS exhibited superior performance in specificity (0.98), accuracy (0.95), and false positive rate (0.04) compared to other detection methods. Although the tested DRS prototype device exhibited limited penetration depth, it shows promise as a method, particularly for the detection of incipient caries.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30208 - Dentistry, oral surgery and medicine
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Diagnostics
ISSN
2075-4418
e-ISSN
2075-4418
Volume of the periodical
13
Issue of the periodical within the volume
11
Country of publishing house
CH - SWITZERLAND
Number of pages
13
Pages from-to
1878
UT code for WoS article
001005390400001
EID of the result in the Scopus database
2-s2.0-85161731361